| | | | | | How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Hint: A not-so-underground installation. |
|
|
|
| |
|
|
|
| | Sponsored | | Lightweight Champion Duct® fiberglass electrical conduit offers easy installation, contributes to lower material and installation costs and is an ideal solution to protect cables running along bridges. |
|
|
|
| |
|
|
|
| | | | Fill in the blank. Insulated conductors and cables used in _____ shall be Types FEP, FEPB, MTW, PFA, RHH, RHW, RHW-2, SA, THHN, THW, THW-2, THHW, THWN, THWN-2, TW, XHH, XHHW, XHHW-2, XHHN, XHWN, XHWN-2, Z, or ZW. |
|
|
|
| |
|
|
|
| | | | Section 215.15 was a new requirement for the 2023 Code meant to increase safety in certain power distribution equipment where feeder conductors terminate. The requirement is one long sentence, so Russ breaks it down piece by piece. |
|
|
|
| |
|
|
|
| | | | See the latest Code violations from NEC Consultant Russ LeBlanc. This edition looks at a FMC calamity and a sloppy slew of code violations. |
|
|
|
| |
|
|
|
| | | Fill in the blank. In dwelling unit bathrooms, not less than one 15A or 20A, 125V receptacle outlet shall be installed within _____ of the outside edge of each bathroom basin. |
|
|
|
| |
| | | Article 408 covers the requirements for switchboards and panelboards that control power and lighting circuits. These rules address the equipment that forms the core of a premises electrical system. For that reason, you should invest the time it takes to become familiar with them. |
|
|
|
| |
|
|
|
| | | The mayor of Omaha, Neb., recently vetoed a city council ordinance adopting the 2023 National Electrical Code (NEC) unamended. After the council failed to override the veto, the city will follow the state in adopting an amended 2023 NEC that rolls back an expansion of ground-fault circuit interrupter (GFCI) requirements. |
|
|
|
| |
| | | These 10 trends are poised to shape next year’s electrical construction market. |
|
|
|
| |
|
|
|
| | | Is that installation for real? Unfortunately, the answer is yes. Back by popular demand, we present the “best of the worst” What's Wrong Here photos from 2024. Read each hint, and then click the next slide to read the analysis from NEC Consultant Russ LeBlanc on each Code violation. |
|
|
| In this video, Russ highlights a classic violation of Sec. 110.26(B). As the video shows, the working space in front of the panelboard is being used for storage. Cluttering the working space in this manner can lead to several issues. Watch now to hear Russ explain the importance of this Code rule. |
|
|
|
| |
| | | Is that installation for real? Unfortunately, the answer is yes. Back by popular demand, we present the “best of the worst” What's Wrong Here photos from 2024. Read each hint, and then click the next slide to read the analysis from NEC Consultant Russ LeBlanc on each Code violation. |
|
|
| Fill in the blank. The maximum distance between supports of straight runs of 1 in. RMC with threaded couplings is ________. |
|
|
|
| |
|
|
|
| | |
|
| | |
|