Maintenance, Repair & Operations

Everything electrical professionals need to know about MRO, including technical advancements and trends in the maintenance, repair and operations of electrical equipment and systems.

Highlights

Photo 2. This worker is attaching the current clamp from a power quality analyzer to a feeder conductor supplying a three-phase panelboard in a data facility. Study power quality to track down some of those “mysterious” equipment problems.

Top Tips to Improve Your Electrical Troubleshooting Skills

Aug. 19, 2024
Avoiding these common mistakes in electrical system evaluation and diagnosis leads to increased efficiency and reduced downtime.
Switchboards and Panelboards

NEC Requirements for Switchboards and Panelboards

Dec. 18, 2024
Switchboards and panelboards are often called “the guts” of a premises wiring system.
ID 130009187 © Leowolfert | Dreamstime.com
dreamstime_xxl_130009187

U.S. Energy Storage Market Hits Record Growth in Q3 2024, Driven by Grid-Scale and Residential Installations

Dec. 16, 2024
The U.S. energy storage market continued its strong growth in Q3 of 2024.
ID 29616560 © Daniel Schweinert | Dreamstime.com
dreamstime_xxl_29616560

Code Quiz of the Week: No. 469

Dec. 16, 2024
Weekly Quiz on the 2023 National Electrical Code
ee_videos_nov_2024

The Top Everyday Electrician Videos of November 2024

Dec. 12, 2024
See which videos from Trevor Ottmann were the most popular with followers of our Instagram, TikTok, and YouTube accounts.
ID 116265799 © Thongchaipeun | Dreamstime.com
Id 116265799 © Thongchaipeun | Dreamstime
ID 340345231 © Chaynam Lek | Dreamstime.com
Construction safety equipment laid out across a grey background. Includes vests, hard hats, rope/tethers, PPE, tools, tape measure, etc.
ID 301427529 | 2024 © ali bin mousa | Dreamstime.com
The 5 Most Memorable Moving Violations Videos of 2024
ID 188775926 © Josepalbert13 | Dreamstime.com
Understanding General Requirements of the NEC, Part 1
ID 321335940 © Weerapat Wattanapichayakul | Dreamstime.com
Wooden blocks that spell out 'quiz' with a light bulb above it

Electrical Troubleshooting Quiz — December 3, 2024

Dec. 3, 2024
In this case, operators have complained about sluggish motors and things not getting started on time at various stages. How would you solve this?
In the typical facility, the plant manager has X amount of discretionary spending power that can be directed toward a single purchase. At each level of management down, discretionary spending is stepped down into smaller amounts. Anything beyond a given manager’s limit must be appealed to the next level up. For example, the Plant Engineer can’t quite swing a purchase of $5200 but the Plant Manager can approve it. This informal arrangement reduces corporate overhead and improves operational efficiency. It does not address whether the spending decisions would make financial sense to the Chief Financial Officer, but the cap at each level keeps any mistakes to a reasonably acceptable loss or misallocation of resources. Beyond the Plant Manager’s limit, there is usually a formal process for getting spending approval. It typically involves filling out a Capital Request (or similarly named form). In well-run companies, the form is very structured. It mostly wants some basic information that will give the reviewer(s) the ability to justify not just the purchase but also the cost of acquiring the capital to do so. Because the funds will typically be borrowed by the corporation, the cost of capital must be balanced against the return on investment. There will be at least one person crunching the numbers to make what is called “the business case” for the proposed spending. Making the business case is something you should do, in some way or another, when considering spending within your approved limits. If the spending is above your approved limits, then the manager above you will need a bit beefier of a business case. The business case must take into account the value obtained versus the money spent. Consider the purchase of a thermographic camera. If you intend to purchase a mid-range camera but nobody at your facility is trained and certified in its use, the purchase is probably a waste of money. You’d be better off getting an entry-level camera and then arranging for a path toward certification if you intend to have that ability in-house and it makes operational and financial sense to do so. And generally, it makes sense to have a person or two with Level I certification so they really understand how to get the most out of a camera system that’s beyond the basic level. On the other hand, if you were a manager at an electrical testing firm with several Level III Thermographers you would be wasting your thermographers if you decided to “save money” by equipping them with only basic or even intermediate camera systems. Your firm needs to be able to troubleshoot problems when that important client calls in a panic. Your thermographers need the tools to do that job, and “cost-saving” on camera systems won’t cut it. Presumably, your clients are smart enough to already have basic camera systems; they just don’t have the expertise to use advanced systems. Sometimes a different logic applies to other types of test equipment. In the typical plant, maintenance electricians need sophisticated DMMs. If they lack the training to use the features that are needed for most effectively keeping equipment running, simply choosing a less capable DMM they already know how to use is not the answer. They need the appropriate DMM along with the training on how to use those features correctly. So far, we haven’t looked at the need to crunch any numbers to make the business case. What we have done is think about the match between the purchase, the problem that needs to be solved, and the ability of the user to solve the problem using that purchase. This sounds like a common sense approach that everyone would naturally take, but people often lose sight of the reason for the purchase in the first place. The tendency is to either go all out on something they can’t use or don’t need, or to “save money” by shortchanging the end users with something that doesn’t allow them to do what they need to do. What about those numbers? When you do a purchase request, a bean counter is going to try to determine the cash flows involved (typically in monthly periods). If you write something like, “The payback period is three years,” they don’t find that helpful. Lenders care that a loan can be serviced, and cash flow is the critical factor in calculating whether it can. Thus, beancounters don’t use payback to determine whether they can afford to borrow. They use the Internal Rate of Return (IRR) or Modified Internal Rate of Return (MIRR). Formulas for both IRR and MIRR have been in spreadsheet programs for over two decades, but before that they were determined using a Business Math Calculator (about $150 in 1990). And before that, they were laboriously calculated by hand. The cash flows that are charted will be either additional revenue generated or losses prevented. To help the person who figuratively wears the green eye shade, tie the use of the test equipment to a revenue stream. A major appliance plant in Tennessee has several production lines that collectively produce $1,560,000 per hour of revenue. Thus each minute of unplanned downtime is quite costly. If the plant electrical engineer there wanted to upgrade test equipment in a way that exceeds the Plant Manager’s spending authority, he needs to help the green eye shade guy do the math. He can cite short case histories from the past two years and briefly explain how having X capability (present in the new equipment, absent in the existing equipment) would have saved Y minutes of downtime (which the green eye shade guy will calculate out in terms of revenue and cash flow). The green eye shade guy also needs to know whether each case history is a one-off that will never recur or if it’s representative of what to expect in the future. You can settle this question with a brief explanation. For example, “The responding technician did not have a [name of test equipment]. Consequently, he had to arrive at the same conclusion by other means to the tune of 24 minutes of downtime he would not have incurred if he’d had a [name of test equipment]. This problem occurred once on Line 2 and twice on Line 4.” Now the green eye shade guy can simply add up the downtime, monetize it, and create the cash flow analysis. And it’s really good for something like a power monitor. For example, “In this particular case the plant did not have a monitoring system capable of detecting short-term bursts of power, which we call transient spikes, and alerting us. Transients happen with no notice, and usually without being detected. The motor shop forensic report shows the main motor failed due to winding insulation failure caused by transients. With a power monitor detecting and reporting those transients, we would have been able to intervene before outright failure, on a scheduled basis. That would have reduced downtime by 57 minutes twice last year alone.” Making the business case for your smaller purchases means simply thinking about what you are trying to accomplish and then making sure you are spending the funds correctly to achieve that goal. But as you go up the food chain, you need to make the picture more clear. And when you appeal to corporate for approval, you need to provide reasonably accurate downtime savings numbers that can be converted by them to revenue loss prevention in specific dollar amounts.
Man staring at wall with hand-drawn question marks and money bags on it

Making the Business Case for Electrical Maintenance Investments

Dec. 3, 2024
Learn tips for correctly matching your purchases with the current problems and crunching the numbers as you go.
EC&M Tech Talk — Optical Fiber Cable – Basics, Construction and Installation

EC&M Tech Talk — Optical Fiber Cable – Basics, Construction and Installation

Dec. 2, 2024
Randy reviews the concepts, cables used, and NEC rules for Optical Fiber Cables.
ID 100533953 © Ramzi Hachicho | Dreamstime.com
dreamstime_xxl_100533953

Code Quiz of the Week: No. 467

Dec. 2, 2024
Weekly Quiz on the 2023 National Electrical Code