| | | | | | Russ looks at an installation where EMT is used as support for other wiring. Using EMT in this way is a violation of Sec. 358.12(2) in the NEC. In addition, Russ points out a violation to Sec. 300.11(C) because a raceway is being used to support cables. Unfortunately, this is a common violation that Russ finds when in the field. Have you ever seen ... |
|
|
|
| |
|
|
|
| | Sponsored | | Unlock your potential with SPARK: The Electrician's Expo’s exceptional educational sessions! Our event offers a curated selection of hand-picked sessions designed to enhance your skills, expand your knowledge, and keep you ahead in the industry. Register now with code SAVE15 to receive a 15% discount on full registration. |
|
|
|
| |
|
|
|
| | | | Fill in the blank. The ampacity of the conductors in type NM cable shall be based on _______ degrees C. |
|
|
|
| |
|
|
|
| | Sponsored | | EXAIR Cabinet Coolers stop electronic control downtime due to heat, dirt and moisture. Learn the many advantages of using these low cost and reliable systems. Learn more in EXAIR's In The Know paper "Cabinet Cooler Advantages". |
|
|
|
| |
|
|
|
| | | | When I first spotted this LB type conduit body mostly covered by the concrete walkway, my first instinct was to assume this was a violation since the concrete would need to be broken up in order to access the wiring inside of the LB. But when I started digging deeper into the wording of Sec. 314.29, I started to question whether my instincts were correct... |
|
|
|
| |
|
|
|
| | | | Fill in the blank. Article 411 covers _____ lighting systems and their associated components. |
|
|
|
| |
|
|
|
| | | | The plumbing pipes located directly above this enclosed panelboard show a great way to violate the dedicated space requirements of Sec. 110.26(E). With no leak protection apparatus installed to protect the electrical equipment, any leak of water or other fluids into the electrical equipment could cause a sudden and catastrophic failure. |
|
|
|
| |
|
|
|
| | | In this episode of EC&M Code Conversations, Editor-in-Chief Ellen Parson and Code Consultant Russ LeBlanc talk about Sec. 300.6 of the NEC and the requirements related to protecting equipment against corrosion and deterioration. |
|
|
|
| |
| | | View three of Trevor Ottmann's most popular TikToks/reels from last month that caught our followers' attention! And make sure to follow us on your preferred social media platforms. |
|
|
|
| |
|
|
|
| | | This photo gallery, sponsored by Zekelman Industries, offers a sneak peek at the companies making it into the Top 20 out of 50 spots, listed in descending order and based on their 2023 electrical sales data. Find out more about the driving forces behind the key players in the electrical contracting business. |
|
|
|
| |
| | Sponsored | Facilities Expo combines electrical solutions, MRO, and green building expertise under one roof. Explore the free expo floor, attend industry talks, and network with professionals. |
|
|
|
| |
|
|
|
| | | How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here's your chance to moonlight as an electrical inspector and second-guess someone else's work from the safety of your living room or office. Can you identify the specific Code violation(s) in this photo? Hint: I wood knot do this... |
|
|
|
| |
| | | Test your knowledge of the NEC with this challenging question. Metal wireways shall not be permitted for _____. |
|
|
|
| |
|
|
|
| | |
|
| | |
|