Ecmweb 3849 210 52a0 Un210 49bweb

Code Q&A

June 20, 2006
When determining the placement for receptacles in a dwelling, is the wall space behind a door required to be considered?


Q. When determining the placement for receptacles in a dwelling, is the wall space behind a door required to be considered?

A. Yes. A receptacle outlet must be installed so no point along the wall space will be more than 6 feet, measured horizontally, from a receptacle outlet [210.52(A)(2)].

According to 210.52(A)(2), wall space is defined as: (1) Any space 2 feet or more in width, unbroken along the floor line by doorways, fireplaces, and similar openings. (2) The space occupied by fixed panels in exterior walls. (3) The space occupied by fixed room dividers, such as freestanding bar-type counters or railings.

About the Author

Mike Holt

Mike Holt is the owner of Mike Holt Enterprises (www.MikeHolt.com), one of the largest electrical publishers in the United States. He earned a master's degree in the Business Administration Program (MBA) from the University of Miami. He earned his reputation as a National Electrical Code (NEC) expert by working his way up through the electrical trade. Formally a construction editor for two different trade publications, Mike started his career as an apprentice electrician and eventually became a master electrician, an electrical inspector, a contractor, and an educator. Mike has taught more than 1,000 classes on 30 different electrical-related subjects — ranging from alarm installations to exam preparation and voltage drop calculations. He continues to produce seminars, videos, books, and online training for the trade as well as contribute monthly Code content to EC&M magazine.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Strut Comparison Chart

Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Electrical Conduit for Bridges Guide

Learn about electrical conduit for bridge projects.

Don't Let Corrosion Disrupt Your Next Project

The Complete Corrosion eGuide for Industrial Electrical Systems will help you avoid corrosion and its effects so you can spec for success for successful project outcomes.

Strut Corrosion Guide

Learn how Champion Strut™ benefits projects with corrosion resistance.