What's Wrong Here?

July 1, 2009
Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?

How well do you know the Code? Think you can spot violations the original installer either ignored or couldn't identify? Here's your chance to moonlight as an electrical inspector and second-guess someone else's work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?

Hint: Pandora's box

Find the Answer


‘TELL THEM WHAT THEY'VE WON…’

Using the 2008 NEC, correctly identify the Code violation(s) in this month's photo — in 200 words or less — and you could win something to put in your toolbox. E-mail your response to [email protected], and we'll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc., valued at more than $125.* The set includes 9.25-in. insulated side-cutting pliers, 10-in. insulated tongue-and-groove pliers, and a 0.25-in. × 6-in. insulated screwdriver. (* Please allow six to eight weeks for delivery of tools.)


May Winners

Our three winners this month were: Glen Coury, electronics engineer, K Company, Kent, Ohio; Carl S. Johnson II, senior aviation lighting specialist, Avcon, Inc., Orlando; and Eric Dixon, electrician, Action Electric, Jonesville, Va. This group identified the following Code violations associated with the rooftop air-conditioner equipment installation.

  • The disconnect switch support (a piece of wood) is not suitable for use in this application [110.3(A)(2)] because it doesn't meet “mechanical strength and durability” requirements.

  • Electrical equipment should be firmly secured to the surface on which it is mounted. [110.13(A) and 300.11].

  • Materials shall be protected from corrosion and deterioration (300.6) and — where exposed to sunlight — shall be listed or identified as sunlight-resistant [300.6(C)(1)].

  • The liquidtight flexible metal conduit (LFMC) is damaged and not supported according to 350.30(A).

Maybe the installer should have taken advantage of 440.14 and mounted the disconnect on the side of the air conditioner unit and not on a chunk of wood.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.