What’s Wrong Here? October 2010

Oct. 21, 2010
Can you identify the Code violation(s) in this photo?

Can you identify the Code violation(s) in this photo?

Hint: Bonding continuity questioned

Find the Answer

How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?

‘Tell Them What They’ve Won...’

Using the 2008 NEC, correctly identify the Code violation(s) in this month’s photo — in 200 words or less — and you could win something to put in your tool­box. E-mail your response to [email protected], and we’ll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc., valued at more than $125.* The set includes 9.25-in. insulated side-cutting pliers, 10-in. insulated tongue-and-groove pliers, and a 0.25-in. 3 6-in. insulated screwdriver. (* Please allow six to eight weeks for delivery of tools.)

August Winners

Our three winners this month include: Steve Vidal, P.E., president, Joseph VJ. Vidal & Sons, Inc., Throop, Pa.; Adam Porter, president, Tricore, Cadiz, Ohio; and John Klouda, foreman, Difazio Electric LLC, Deer Park, N.Y. In addition to pointing out the obvious lack of circuit identification in this photo, all three raised questions with the armored cable entering the panel.

As noted in 408.4, “Every circuit and circuit modification shall be legibly identified as to its clear, evident, and specific purpose or use.” In addition, the rule goes on to say, “The identification shall be included in a circuit directory that is located on the face or inside of the panel door in the case of a panelboard, and located at each switch on a switchboard.”

Two other sections of the Code that could be cited by the AHJ are 320.24(B) and 320.30(B). The bend radius looks pretty tight on one of the AC cables entering the right side of the panel and may violate the minimum bend radius of “five times the external diameter of the metallic sheath.” Furthermore, the requirement of securing the AC cable within 12 in. of the cabinet may also be a violation here, although the photo is cropped just a little too close to offer 100% verification.

About the Author

Joe Tedesco

Tedesco served the industry in many roles during his career. He was a director, senior electrical code instructor for National Technology Transfer, Inc. and American Trainco, Inc.. He was also a codes, standards and seminar specialist for the International Association of Electrical Inspectors and an electrical field service specialist for the National Fire Protection Association in Quincy, Mass. He ran his own business as an NEC consultant and is a Massachusetts licensed master electrician and journeyman electrician and certified electrical inspector (one and two family 2A; General 2B, and Plan Review, 2C). Tedesco also wrote articles for CEE News and EC&M (Code Violations Illustrated and What's Wrong Here?) for more than 15 years and helped launched the Moving Violations video series.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Don't Let Burn-Through Threaten Another Data Center or Utility Project

Get the No Burn-Through Elbow eGuide to learn many reasons why Champion Fiberglass elbows will enhance your data center and utility projects today.

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.