What’s Wrong Here? Hint: It's Mind Bottling

Jan. 16, 2013
Can you identify the Code violation(s) in this photo?
How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo? Note: Submitted comments must include specific references from the 2011 NEC.

Hint: It's Mind Bottling

‘Tell Them What They’ve Won...’

Using the 2011 NEC, correctly identify the Code violation(s) in this month’s photo — in 200 words or less — and you could win something to put in your tool­box. E-mail your response, including your name and mailing address, to [email protected], and Russ will select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Note that submissions without an address will not be eligible to win. Winners will receive a fluorescent lighting tester from Milwaukee Tool, valued at $199. The product allows complete lamp, ballast, and pin testing, before or after install, without dismantling fixtures.

(*Please allow six to eight weeks for delivery of tools.)

November Winners

Our winners this month include: Vincent Hueber, P.E., facility engineer, Syracuse Housing Authority, Syracuse, N.Y.; Perry R. Kruse, owner, Perry Kruse Electric, Northfield, Minn.; and Jayson Sorum, electrician, Grand Forks Public School District, Grand Forks, N.D. They all correctly identified the following violations associated with this damaged conduit.

It looks like this installer may have been absent from class on pipe bending day, or perhaps he took the class, “How to Bend Pipe with Hammers 101.” In any case, the EMT has been damaged, and its internal diameter has been effectively reduced. This is clearly a violation of 358.24, as proper pipe bending techniques were not used on this EMT. The installation is also not very “neat and workmanlike,” as required by 110.12.

Damaging the EMT in this manner can cause problems with the conductors as they get pulled through the pipe. Imagine yourself trying to pull a bundle of conductors through the kinks on that bend. Some of the kinks in this pipe are so bad that they could even prevent the wires from being pulled in at all.

Many different types of pipe benders are available for electricians to use. Hammers, however, don’t make for a good pipe bender!

About the Author

Russ LeBlanc | Owner

Russ started in the electrical trade as an apprentice in 1985. He worked his way up to become a Journeyman Electrician and then eventually became a Master Electrician and Licensed Construction Supervisor. In 1999 Russ become an Electrical Instructor for The Peterson School of Engineering in Massachusetts where he developed his passion for teaching, and quickly became Department Head of Electrical Instruction. Russ has taught thousands of apprentices, electricians, engineers, inspectors, and other electrical professionals during his career as an instructor. He continues to provide electrical professionals with Electrical Code seminars, Arc-Flash Awareness training seminars and educational material through his LeBlanc Consulting Services in North Reading, MA whose specialty is educating electricians. He has been an active member of the NFPA Electrical Section and has authored hundreds of National Electrical Code proposals and comments which have become Code rules to improve the safety for the electrical industry. Russ is also an IAEI certified Electrical Inspector.

Please visit www.russleblanc.net for more information.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.