Illustrated Catastrophes

Oct. 1, 2005
As usual, never consider the following commentary associated with these photos as a formal interpretation of the National Electrical Code (NEC). Without criticizing anyone or any product, the following scenarios present us with serious safety questions. All references are based on the 2005 NEC. FORK IT OVER DUDE While performing work at a government site, Gary Hack of Benet Labs, Department of Army,

As usual, never consider the following commentary associated with these photos as a formal interpretation of the National Electrical Code (NEC). Without criticizing anyone or any product, the following scenarios present us with serious safety questions.

All references are based on the 2005 NEC.

FORK IT OVER DUDE

While performing work at a government site, Gary Hack of Benet Labs, Department of Army, New York, stumbled across this homemade heating unit that employees were to flash cook their lunch. “I couldn't find a UL label on it,” Hack wrote.

Although the NEC doesn't specifically prohibit such a contraption, the situation does present some very serious personal safety concerns. One particular section of the Code worth reviewing is 110.3, Examination, Identification, Installation, and Use of Equipment. Section (A) of this rule focuses on examination and states in part, “In judging equipment, considerations such as: suitability for installation and use in conformity with the provisions of this Code, heating effects under normal conditions of use and also under abnormal conditions likely to arise in service, arcing effects, and other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment.”

NEW WAVE AQUARIUM?

Phil Petroska, NACHI certified home inspector, North Country Home Inspections, Harrison, Maine, ran across this unique light fixture during a recent home inspection. No, the water filled globe didn't contain a goldfish.

The evidence of water in this globe shouldn't be blamed on the location of this luminaire. The water was most likely the result of a flooded second floor bathroom, or a leak in the roof that was supposed to be fixed. However, it is a good reminder of the requirements of 410.4(A), Luminaires (Fixtures) in Specific Locations, which states, “Luminaires (fixtures) installed in wet or damp locations shall be installed so that water cannot enter or accumulate in wiring compartments, lampholders, or other electrical parts. All luminaries (fixtures) installed in wet locations shall be marked, ‘Suitable for Wet Locations.’ All luminaires (fixtures) installed in damp locations shall be marked, ‘Suitable for Wet Locations’ or ‘Suitable for Damp Locations.’”

Found a Code violation? E-mail your photos to Joe Tedesco at [email protected].

About the Author

Joe Tedesco

Tedesco served the industry in many roles during his career. He was a director, senior electrical code instructor for National Technology Transfer, Inc. and American Trainco, Inc.. He was also a codes, standards and seminar specialist for the International Association of Electrical Inspectors and an electrical field service specialist for the National Fire Protection Association in Quincy, Mass. He ran his own business as an NEC consultant and is a Massachusetts licensed master electrician and journeyman electrician and certified electrical inspector (one and two family 2A; General 2B, and Plan Review, 2C). Tedesco also wrote articles for CEE News and EC&M (Code Violations Illustrated and What's Wrong Here?) for more than 15 years and helped launched the Moving Violations video series.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Don't Let Burn-Through Threaten Another Data Center or Utility Project

Get the No Burn-Through Elbow eGuide to learn many reasons why Champion Fiberglass elbows will enhance your data center and utility projects today.

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.