Quizzes http://ecmweb.com/taxonomy/term/6617/more en Code Quiz: Metal Conduit Grounding Requirements for Coaxial Cables http://ecmweb.com/quizzes/code-quiz-metal-conduit-grounding-requirements-coaxial-cables <div class="node-body article-body">When installing communication wires and cables in cable routing assemblies, vertical runs of the cable routing assemblies shall be supported at intervals not to exceed _______, unless listed for other support intervals, and shall not have more than one joint between supports</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-metal-conduit-grounding-requirements-coaxial-cables" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-metal-conduit-grounding-requirements-coaxial-cables#comments Quizzes Silver Thu, 09 Apr 2015 13:50:00 +0000 113571 at http://ecmweb.com Code Quiz: Vertical Support Requirements for Cable Routing Assemblies http://ecmweb.com/quizzes/code-quiz-vertical-support-requirements-cable-routing-assemblies <div class="node-body article-body">When installing communication wires and cables in cable routing assemblies, vertical runs of the cable routing assemblies shall be supported at intervals not to exceed _______, unless listed for other support intervals, and shall not have more than one joint between supports</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-vertical-support-requirements-cable-routing-assemblies" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-vertical-support-requirements-cable-routing-assemblies#comments Quizzes Silver Thu, 26 Mar 2015 13:50:00 +0000 111761 at http://ecmweb.com Code Quiz: Horizontal Support Requirements for Cable Routing Assemblies http://ecmweb.com/quizzes/code-quiz-horizontal-support-requirements-cable-routing-assemblies <div class="node-body article-body">When installing communication wires and cables in cable routing assemblies, horizontal supports for cable routing assemblies shall be installed at intervals not to exceed _____ at each end or joint unless listed otherwise. In no case shall the distance between supports exceed _____.</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-horizontal-support-requirements-cable-routing-assemblies" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-horizontal-support-requirements-cable-routing-assemblies#comments Quizzes Silver Thu, 12 Mar 2015 13:40:00 +0000 110601 at http://ecmweb.com Code Quiz: Installation of Fire-Resistive Cable Systems http://ecmweb.com/quizzes/code-quiz-installation-fire-resistive-cable-systems <div class="node-body article-body">Where a fire-resistive system is listed to be installed in a raceway, the raceway enclosing the system is permitted to be which one of the following? </div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-installation-fire-resistive-cable-systems" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-installation-fire-resistive-cable-systems#comments Quizzes Silver Thu, 26 Feb 2015 21:40:00 +0000 109451 at http://ecmweb.com Code Quiz: Fire-Resistive Cable System Grounding Requirements http://ecmweb.com/quizzes/code-quiz-fire-resistive-cable-system-grounding-requirements <div class="node-body article-body">When installing a fire-resistive system requiring an equipment grounding conductor (EGC), the EGC shall use the same fire-rated cable described in the system, unless installed in compliance with which of the following requirements? </div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-fire-resistive-cable-system-grounding-requirements" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-fire-resistive-cable-system-grounding-requirements#comments Quizzes Silver Thu, 12 Feb 2015 21:40:00 +0000 108261 at http://ecmweb.com Code Quiz: Junction Box Requirements http://ecmweb.com/quizzes/code-quiz-junction-box-requirements <div class="node-body article-body">When installing junction boxes in underfloor raceways, the junction boxes shall be ______ the floor grade and _____ to prevent the free entrance of water or concrete.</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-junction-box-requirements" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-junction-box-requirements#comments Quizzes Silver Thu, 22 Jan 2015 22:33:00 +0000 107201 at http://ecmweb.com Code Quiz: Grounding of Strut-Type Channel Raceway http://ecmweb.com/quizzes/code-quiz-grounding-strut-type-channel-raceway-0 <div class="node-body article-body">Where a strut-type channel raceway enclosure uses a snap-fit metal cover to achieve electrical continuity in accordance with the listing,</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-grounding-strut-type-channel-raceway-0" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-grounding-strut-type-channel-raceway-0#comments Quizzes Silver Thu, 08 Jan 2015 20:54:00 +0000 106011 at http://ecmweb.com Code Quiz: Motor and Controller Disconnecting Means http://ecmweb.com/quizzes/code-quiz-motor-and-controller-disconnecting-means <div class="node-body article-body">With respect to a motor circuit application, the disconnecting means at the controller location is “in sight from” and 15 ft from the controller.</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-motor-and-controller-disconnecting-means" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-motor-and-controller-disconnecting-means#comments Quizzes Silver Thu, 18 Dec 2014 15:41:00 +0000 58091 at http://ecmweb.com Code Quiz: Ampacity of Generator Conductors http://ecmweb.com/quizzes/code-quiz-ampacity-generator-conductors <div class="node-body article-body">Excluding any exception(s), what is the minimum ampacity of the conductors from the generator terminals to first distribution device containing overcurrent protection? </div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-ampacity-generator-conductors" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-ampacity-generator-conductors#comments Quizzes Silver Thu, 04 Dec 2014 15:41:00 +0000 57201 at http://ecmweb.com Code Quiz: Handhole Enclosure Requirements http://ecmweb.com/quizzes/code-quiz-handhole-enclosure-requirements <div class="node-body article-body">With respect to wiring entries, such as a schedule 80 PVC raceway installed underground entering into a handhole enclosure, a schedule 80 PVC raceway shall be mechanically and electrically connected to the handhole enclosure by ______.</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-handhole-enclosure-requirements" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-handhole-enclosure-requirements#comments Quizzes Silver Thu, 20 Nov 2014 22:05:00 +0000 56461 at http://ecmweb.com