Quizzes http://ecmweb.com/taxonomy/term/6617/more en Code Quiz: Raceways in Wet Locations Abovegrade http://ecmweb.com/quizzes/code-quiz-raceways-wet-locations-abovegrade <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body"><p>When installing a THHN / THWN insulated conductor in a raceway that is located on the outside wall of a building or structure (wet location), the choice for the type of conductor insulation is permitted to be based on _____________.</p> <p>A. the use of THHN insulation rating, based on a dry location rating, as the inside of the raceway is considered to be a dry location. The installation shall also comply with&nbsp; 310.10(C).</p></div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-raceways-wet-locations-abovegrade" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-raceways-wet-locations-abovegrade#comments Quizzes Silver Fri, 22 Aug 2014 01:55:00 +0000 51651 at http://ecmweb.com Code Quiz: Sizing the Grounding Conductor for a Single Raceway http://ecmweb.com/quizzes/code-quiz-sizing-grounding-conductor-single-raceway <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">Why is the term “grounded conductor” included in the heading of new Table 250.102(C)(1)?</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-sizing-grounding-conductor-single-raceway" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-sizing-grounding-conductor-single-raceway#comments Quizzes Silver Fri, 08 Aug 2014 01:55:00 +0000 50481 at http://ecmweb.com Code Quiz: Service Masts as Supports http://ecmweb.com/quizzes/code-quiz-service-masts-supports-0 <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">When attaching service-drop or overhead service conductors to a service mast, they shall not be attached between a weatherhead or the end of a conduit and a coupling,</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-service-masts-supports-0" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-service-masts-supports-0#comments Quizzes Silver Fri, 25 Jul 2014 01:55:00 +0000 50021 at http://ecmweb.com Code Quiz: Hubs and Service Masts http://ecmweb.com/quizzes/code-quiz-hubs-and-service-masts <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">When installing a rigid metal conduit that serves as a service mast, the hub installed as part of this system shall be __________.</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-hubs-and-service-masts" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-hubs-and-service-masts#comments Quizzes Silver Fri, 11 Jul 2014 01:55:00 +0000 48731 at http://ecmweb.com Code Quiz: Underground Service Conductors http://ecmweb.com/quizzes/code-quiz-underground-service-conductors <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">When installing disconnecting means for outside feeders and branch circuits, if the disconnecting means installed in accordance with Sec. 225.32 of the 2014 NEC is not readily accessible, it shall be _________.</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-underground-service-conductors" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-underground-service-conductors#comments Quizzes Silver Thu, 26 Jun 2014 15:19:00 +0000 48001 at http://ecmweb.com Code Quiz: Disconnecting Means for Outside Feeders and Branch Circuits http://ecmweb.com/quizzes/code-quiz-disconnecting-means-outside-feeders-and-branch-circuits <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">When installing disconnecting means for outside feeders and branch circuits, if the disconnecting means installed in accordance with Sec. 225.32 of the 2014 NEC is not readily accessible, it shall be _________.</div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-disconnecting-means-outside-feeders-and-branch-circuits" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-disconnecting-means-outside-feeders-and-branch-circuits#comments Quizzes Silver Thu, 12 Jun 2014 15:19:00 +0000 47541 at http://ecmweb.com Branch Circuits for EV Charging Equipment Outlets http://ecmweb.com/quizzes/branch-circuits-ev-charging-equipment-outlets <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">When installing outlets for the purpose of charging electric vehicles, the branch circuit supplying the outlets shall ___________.</div> <div class="field-content-focus"> <span>Content Classification:&nbsp;</span> influencer </div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/branch-circuits-ev-charging-equipment-outlets" target="_blank">read more</a></p> http://ecmweb.com/quizzes/branch-circuits-ev-charging-equipment-outlets#comments Quizzes Silver Thu, 22 May 2014 16:08:00 +0000 46651 at http://ecmweb.com Code Quiz: AFCI and GFCI Protection http://ecmweb.com/quizzes/code-quiz-afci-and-gfci-protection <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">In which area of a dwelling unit are both GFCI and AFCI protection required?</div> <div class="field-content-focus"> <span>Content Classification:&nbsp;</span> influencer </div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-afci-and-gfci-protection" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-afci-and-gfci-protection#comments Quizzes Silver Thu, 08 May 2014 14:20:00 +0000 45821 at http://ecmweb.com Code Quiz: Ground Fault Protection of Equipment http://ecmweb.com/quizzes/code-quiz-ground-fault-protection-equipment <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">Which of the following installations does not require ground fault protection of equipment?</div> <div class="field-content-focus"> <span>Content Classification:&nbsp;</span> influencer </div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-ground-fault-protection-equipment" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-ground-fault-protection-equipment#comments Quizzes Silver Thu, 24 Apr 2014 18:17:00 +0000 45221 at http://ecmweb.com Code Quiz: GFCI Protection http://ecmweb.com/quizzes/code-quiz-gfci-protection <div class="field-byline"> By Steven Owen, National Code Seminars </div> <div class="node-body article-body">Which of the following items may be wired directly (i.e., hard-wired) without cord-and-plug connection, thus omitting the requirement for GFCI protection?</div> <div class="field-content-focus"> <span>Content Classification:&nbsp;</span> influencer </div> <div class="og_rss_groups"></div><p><a href="http://ecmweb.com/quizzes/code-quiz-gfci-protection" target="_blank">read more</a></p> http://ecmweb.com/quizzes/code-quiz-gfci-protection#comments Quizzes Silver Thu, 10 Apr 2014 16:56:00 +0000 44391 at http://ecmweb.com