Ecmweb 8426 Failedconductor
Ecmweb 8426 Failedconductor
Ecmweb 8426 Failedconductor
Ecmweb 8426 Failedconductor
Ecmweb 8426 Failedconductor

Broken Neutral Conductor Leads to Lifeguard's Shock Drowning

Sept. 14, 2016
Rachel Rosoff, 17, was found in a pool in a Raleigh, N.C., neighborhood on Sept. 3 and pulled from the water.

The failure of a pool pump motor and a broken neutral conductor resulted in the shock and subsequent death of a teen Raleigh lifeguard. Rachel Rosoff, 17, was found in a pool in a Raleigh, N.C., neighborhood on Sept. 3 and pulled from the water.

A relative told WRAL News that Rosoff was alone at the pool at the time of her death. They believe she was holding a metal bar for support when she reached into the water to check the chemicals.

According to an inspection report issued by Wake County Planning, Development and Inspections on Monday, the motor on the pool pump failed and Phase A faulted to ground. But since the neutral conductor was "open (broken/could not conduct electricity)" it was unable to provide an effective ground-fault current path. “The current then followed the only path available to it, the pool water, creating a voltage gradient across the pool and pool equipment,” the report said.

For more details and photos of the electrical equipment from the investigation, see the original inspection report.

This is an update of a story EC&M posted on Sept. 9, 2016.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.