When calculating the ampacity of a common neutral conductor installed as part of a circuit for an outside feeder or branch circuit, the ampacity of the common neutral conductor shall comply with which of the following?

When calculating the ampacity of a common neutral conductor installed as part of a circuit for an outside feeder or branch circuit, the ampacity of the common neutral conductor shall comply with which of the following?
Note: This applies to lighting equipment installed outdoors.

  1. It shall always be the same size as the largest ungrounded phase conductor.
  2. The maximum net calculated load current between the neutral conductor and all ungrounded conductors connected to any one phase of the circuit.
  3. The maximum net calculated load current between the neutral conductor and the equipment grounding conductor.
  4. The minimum net calculated load current between the neutral conductor and all ungrounded conductors connected to any one phase of the circuit.

Answer: B

Article 225 covers the rules for installation of outside branch circuits and feeders. As noted in 225.7(B), "… the maximum net calculated load current between the neutral conductor and all ungrounded conductors connected to any one phase of the circuit." This applies to lighting equipment installed outdoors.

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at [email protected].

About the Author

Steven Owen

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.