Code Quiz

Oct. 26, 2007
A new service consisting of 6 individual disconnect switches has been installed outdoors, on the back side of a small retail shopping center

Q. A new service consisting of 6 individual disconnect switches has been installed outdoors, on the back side of a small retail shopping center. One of the disconnect switches has been installed remote from the others. The disconnect installed remote from the others is for the water pump intended for fire protection. Is this installation NEC compliant?

  1. Yes, because the disconnect switches can be installed in any location and in any grouping of the installers choice — no NEC requirement.
  2. Yes, because one of the two to six service disconnecting means is permitted to be installed remote from the others that are grouped together in one location if it meets the requirements of the exception associated with the grouping requirement.
  3. No, because retail shopping locations require that all service disconnects be installed in a locked room in a separate building adjacent to the shopping area.
  4. No, because all service disconnects need to be installed in indoor locations only.

Answer: B

One of the two to six service disconnecting means is permitted to be installed remote from the others that are grouped together in one location if it meets that requirements of the exception associated with the grouping requirement. [230.72(A)(EX)]

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at [email protected].

About the Author

Steven Owen

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Don't Let Burn-Through Threaten Another Data Center or Utility Project

Get the No Burn-Through Elbow eGuide to learn many reasons why Champion Fiberglass elbows will enhance your data center and utility projects today.

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.