In general, without exception, the main disconnecting means for an electrically driven or controlled irrigation machine shall meet which of the following requirements?

In general, without exception, the main disconnecting means for an electrically driven or controlled irrigation machine shall meet which of the following requirements?

  1. provide overcurrent protection
  2. be located at the point of connection of electric power to the irrigation machine, or be visible and not more than 50 ft from the irrigation machine
  3. be readily accessible
  4. be capable of being locked in the open position
  5. all of the requirements noted in answers a, b, c and d above

Answer: E

The main disconnecting means requirements for electrically driven or controlled irrigation machines are listed in Section 675.8(B) of the 2011 NEC. In general, without exception, the main disconnecting means for an electrically driven or controlled irrigation machine provide overcurrent protection, be located at the point of connection of electric power to the irrigation machine, or be visible and not more than 50 ft from the irrigation machine, and shall be readily accessible and capable of being locked in the open position.

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at [email protected].

About the Author

Steven Owen

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.

Champion Strut Catalog

Champion Fiberglass is the most advanced manufacturing facility of fiberglass conduit, fiberglass bridge drain and fiberglass strut systems in the world. Its well-trained and ...

8 Types of Electrical Conduit and Their Uses

Electrical conduit is a tube or raceway used to house and protect electrical wires within a building or structure. From data centers to underground subways to ports and bridges...

Xpress Elbows Guide for Industrial Construction

Learn how to get expedited elbows shipped within 2 days.