AFCI breakers
Apr 23, 2007,
These circuit breakers feature Trip-Alert, an LED indication system that identifies which electrical fault condition induced tripping —arc fault, ground fault, or overload/short circuit...
Recessed fluorescent light
Apr 16, 2007,
The P83-26ICATDM recessed fixture uses a standard 26W compact fluorescent triple-tube lamp and works with a standard incandescent dimmer...
Cable bundlers
Apr 9, 2007,
Cablo Snap secures cable bundles to wire cable tray and helps eliminate over-tightened cable ties. According to the company, the wide, flared design eliminates “pinched” data cables, offering enhanced signal protection...
Building wire
Apr 2, 2007,
No Lube SIMpull THHN building wire eliminates the need for electrical contractors to lubricate feeder-sized THHN to pull it through conduit...
Voltage Tester Goes Directly to the Source
Apr 1, 2007, By Stefanie Kure, Senior Associate Editor
John Dickinson may be a systems engineer/electrician at a private college in Philadelphia, but it didn't take someone with his advanced knowledge to realize...
Focus on Power Distribution Equipment
Apr 1, 2007,
Rack PDU P1000 Series rack power distribution units (PDUs) are available for both vertical and horizontal applications. The PDUs feature 18 AWG cold-rolled...
Compression EMT
Mar 26, 2007,
The Kwik-Fit Compression EMT features an integrated steel compression coupling that, according to the company, reduces installation time and eliminates the need to purchase and store separate couplings...
Branch-circuit monitoring system
Mar 19, 2007,
Designed for incorporation into new or existing data centers, the J Comm branch-circuit monitoring system (BCMS) fits under the raised floor and monitors current, voltage, and other power-related measures for up to 168 branch breakers...
Arc flash protection
Mar 12, 2007,
The FlashGard low-voltage motor control center (MCC) offers an insulated horizontal bus, an insulated labyrinth vertical bus, shutters to isolate the vertical bus when a unit is removed, and finger-safe components inside the units...
Stackable shims/spacers
Mar 5, 2007,
Secura-Lets stackable shims and spacers for wiring devices prevent arcing due to unwanted movement and also prevent broken or cracked faceplates...
Focus on Software
Mar 1, 2007,
Safety grip selection The ez-Calc software CD allows users to choose the appropriate wire management device for their application requirements. The software...
Conduit Marking Device is a Knockout
Mar 1, 2007, By Stefanie Kure, Senior Associate Editor
After working as a commercial electrician/foreman for more than 11 years, Brent Galbreth, president of Deviser, Inc., Winchester, Calif., knew there had...
Design software
Feb 26, 2007,
AcceliCAD 2007 is a CAD platform that provides compatibility with industry-standard file formats, commands, and methods. Enhancements include floating prompt menus and polar angle tracking...
Transient voltage surge suppressor
Feb 19, 2007,
The Strikesorb transient voltage surge suppression (TVSS) module provides uninterrupted protection from surge currents of up to 200kA. In addition, the module meets the requirements of the recently revised UL-1449 (2nd edition) standard without resorting to the use of internal fuses...
Cordless tools
Feb 12, 2007,
The IQV Series of cordless tools includes the W040 ¼-in. quick-change Impactool, the W150 3/8-in. Impactool, the W360 ½-in. Impactool, as well as two drill/drivers — the 19.2V D650 and 14.4V D550...