What's Wrong Here?
Jul 1, 2010 12:00 PM, By Brian J. McPartland, NEC Consultant
Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?
How well do you know the Code? Think you can spot violations the original installer either ignored or couldn't identify? Here's your chance to moonlight as an electrical inspector and second-guess someone else's work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?
Hint: Method of support
‘TELL THEM WHAT THEY'VE WON…’Using the 2008 NEC, correctly identify the Code violation(s) in this month's photo — in 200 words or less — and you could win something to put in your toolbox. E-mail your response to electrical.group@penton.com, and we'll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc., valued at more than $125. (Please allow six to eight weeks for delivery of tools.)
May Winner
This month's winners were: Timothy F. May, master electrician, Westphal & Co., Evansville, Wis.; Ted Worst, engineer, Allied Electric, Inc., Grand Rapids, Mich.; and Bill Moore, owner, Northfield Electric, New York, N.Y.
The first violation is the use of an EMT connector to secure the Type MC cable to the enclosure. Use of the EMT connector with the Type MC cable violates 300.15. The second paragraph of this section says, “Fittings shall be used only with the specific wiring methods for which they are designed and listed.” That wording is very restrictive, and the use of any fitting that is not “designed and listed” for the wiring method in question constitutes a Code violation.
Another violation is use of a 43 1½-in.
Some noted that the box should have a barrier, because there are orange-colored conductors within the enclosure, which is the color coding typically used for 480/277V system conductors to satisfy 404.8(B). That section states, “A snap switch shall not be grouped or ganged within the same enclosure with other snap switches, receptacles, or similar devices, unless they are arranged so that voltage between adjacent devices does not exceed 300V, or unless they are installed in enclosures equipped with identified, securely installed barriers between adjacent devices.” In this case, the conductors are all operating at 120V to neutral, so there is no violation of 404.8(B). However, the means of branch circuit conductor identification required by 210.5(C) does not seem to have been satisfied.
Want to use this article? Click here for options!
© 2012 Penton Media, Inc.
Code Challenge
Code Quiz
May 10, 2012 12:29 PM, By Steven Owen, National Code Seminars
When installing a shielded cable or a twisted pair cable in a Class I, Division 1 location where a cable seal is required, when is it not required to remove the shielding material or separate the twisted pairs of those type cables?...
More Code Quizzes
Code Q&A
May 24, 2012 10:42 AM, By Mike Holt, NEC Consultant
Q. What labeling does the Code require in regard to arc flash hazard warning?...
More Code Q&As
Acceptable Use Policy blog comments powered by Disqus
advertisement
what's wrong here?
What's Wrong Here?
May 10, 2012 12:44 PM
View all What's Wrong Here?
What's Wrong Here
Sponsored By:
product spotlight
EV charger tester
May 25, 2012 8:26 AM
The Electrician is portable tester that verifies critical power and safety requirements of electric vehicle (EV) chargers...
View all 2012 Product Spotlights
Free Product Info
Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.