What's Wrong Here?

Dec 27, 2007 9:55 PM, By Joe Tedesco, NEC Columnist

Hint: Low rent, no heat

Gary Parker, a professional engineer with Burns & McDonnell in Centennial, Colo., sent us this photo of a circuit breaker panelboard installation that has obviously gone through some changes that do not comply with the NEC.

“We found this installation on the exterior of a water storage tank,” says Parker. “The interior cover of this cabinet was nowhere to be found. It was probably lost when the "pigtail" cord and cap was added. These circuits supplied 120V power to the tank’s cathodic protection rectifier and level transmitter. When you look close at the bottom of the panel, you can see the terminal bar with grounded (neutral) and grounding conductors connected together.

“I am sure the wasps enjoyed their warm home on top of the circuit breaker. We’re currently removing and replacing this setup with all new Code-complying equipment and wiring methods.”

Hey Gary, I think the cover is over there near the pile of trash buried under the leaves. These exposed conductors are readily accessible; just have to open the door! I see that they didn’t even run an equipment-grounding conductor from the cord, probably because it didn’t have one.

The method used here to supply the cord cap pigtail from this location is not one that is recognized by Art. 400. I imagine it was only meant to be “temporary,” and just overlooked; however, this would not meet the requirements listed in Art. 590 either.

> Try Another Quiz

Want to use this article? Click here for options!



Acceptable Use Policy
blog comments powered by Disqus

what's wrong here?

What's Wrong Here?

Nov 5, 2009 11:50 AM

What's Wrong Here?

Oct 22, 2009 11:16 PM

What's Wrong Here?

Oct 8, 2009 3:32 PM

View all What's Wrong Here?

product of the week

LED light engine

November 2, 2009

LED light engine

View all 2009 Products of the Week

Recent Comments

More...


EC&M TV

Exterior Fixture Box for Brick or Stone

Installing a fixture box in a brick or stone wall just got easier with Arlington’s new adjustable depth box!

Southwire's 2009 Cable Innovation Road Show

Gain years worth of insight in only 2-1/2 hours with Southwire’s 2009 Cable Innovation Road Show with Grounding Seminar. The agenda is packed with valuable information that focuses on installation tips!

Listen
Sizing Gen-Sets: Facts, Hints, and Good Judgment
Listen

The complexities of today’s commercial or industrial facility, with their equipment environment of linear and nonlinear loads, places a whole new light on sizing engine-generator sets.

Arc Mitigation - A Total System Approach
There’s no question the risk of arc flash hazards is real in the electrical industry. What many don’t always realize is the impact in business interruption from such events typically far outweighs the physical damage to equipment. View this On Demand Webinar!

Implementing an Industrial Ethernet Infrastructure that's Built to Last
This webinar explores the key benefits of implementing a robust complete, end-to-end Industrial Ethernet solution – from cabling and connectivity, to active components and associated hardware. View this On Demand Webinar!

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

rss icon

rss

Browse Back Issues

Browse Back Issues