What's Wrong Here? January 2012
Jan 1, 2012 9:00 AM, By Joe Tedesco, NEC Consultant
Can you identify the Code violation(s) in this photo?
How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?
Hint: Would you consider this an approved use of electrical tape?
‘Tell Them What They’ve Won...’
Using the 2011 NEC, correctly identify the Code sections that show violation(s) in this month’s photo — in 200 words or less — and you could win something to put in your toolbox. E-mail your response to joseph.tedesco@yahoo.com, and we’ll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc., valued at more than $125.* The set includes 9.25-in. insulated side-cutting pliers, 10-in. insulated tongue-and-groove pliers, and a 0.25-in. 3 6-in. insulated screwdriver. (* Please allow six to eight weeks for delivery of tools.)
NOVEMBER WINNERS
We had three winners this month: Anuj Vyas, P.E., electrical engineer, Power Distribution Group, Collider-Accelerator Department, Brookhaven National Lab, Upton, N.Y.; Steven G. Rankin, P.E., senior electrical engineer, CB&I, Tyler, Texas; and Chris Apicella, industrial maintenance student, Tennessee Technology Center, Hillsboro, Tenn. They all picked up on the improper bonding jumper connection rather quickly. Here’s what these three had to say:
As you can see in the photograph, the bonding jumper is wrapped around the conduit. According to the requirements of 250.102(E)(2), if installed on the outside of a raceway or enclosure, “the length of the bonding jumper or conductor, or equipment bonding jumper shall not exceed 1.8 m (6 ft) and shall be routed with the raceway or enclosure.” With no measurements in the photo, how do we know the length of the bonding jumper has not exceeded the 6-ft limitation?
It’s also important to note that a bonding jumper should be the same length as the raceway so the impedance increase is insignificant.
I see this type of installation all the time out in the field and am glad someone is addressing it.
Want to use this article? Click here for options!
© 2012 Penton Media, Inc.
Code Challenge
Code Quiz
May 10, 2012 12:29 PM, By Steven Owen, National Code Seminars
When installing a shielded cable or a twisted pair cable in a Class I, Division 1 location where a cable seal is required, when is it not required to remove the shielding material or separate the twisted pairs of those type cables?...
More Code Quizzes
Code Q&A
May 24, 2012 10:42 AM, By Mike Holt, NEC Consultant
Q. What labeling does the Code require in regard to arc flash hazard warning?...
More Code Q&As
Acceptable Use Policy blog comments powered by Disqus
advertisement
what's wrong here?
What's Wrong Here?
May 10, 2012 12:44 PM
View all What's Wrong Here?
What's Wrong Here
Sponsored By:
product spotlight
EV charger tester
May 25, 2012 8:26 AM
The Electrician is portable tester that verifies critical power and safety requirements of electric vehicle (EV) chargers...
View all 2012 Product Spotlights
Free Product Info
Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.