What's Wrong Here? November 2011
Nov 22, 2011 4:37 PM, Joe Tedesco, NEC Consultant
Can you identify the Code violation(s) in this photo?
How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?
Hint: Taking the long route
‘Tell Them What They’ve Won...’
Using the 2011 NEC, correctly identify the Code sections that show violation(s) in this month’s photo — in 200 words or less — and you could win something to put in your toolbox. E-mail your response to joseph.tedesco@yahoo.com, and we’ll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc., valued at more than $125.* The set includes 9.25-in. insulated side-cutting pliers, 10-in. insulated tongue-and-groove pliers, and a 0.25-in. 3 6-in. insulated screwdriver. (* Please allow six to eight weeks for delivery of tools.)
SEPTEMBER WINNERS
We had three winners this month: Brandon McCoy, foreman, G&G Systems, Henderson, Nev.; Larry Lowe, reliability engineer, Flint Ink, Huntington, W. Va.; and Bill Butler, estimator/project manager, Bayshore Electric, Inc., Daytona Beach, Fla. Each one of them had some interesting observations on this bird nest-filled conduit body — the best one being, “the feathers and twigs in this LB do not qualify as sealing material.”
The missing cover for the conduit body is a violation of 314.17(A) and 314.28(C). This exposes the cable to corrosion and deterioration (and even wild birds!), which is a violation of 300.6. As noted above, feathers and twigs do not qualify as an approved sealing material per 300.7. The conductor exiting the conduit body is now exposed and unprotected from physical damage, which is a violation of 300.4 and 300.5(D)(2). The open and exposed holes in the brick wall at both locations in this photo also create a potential fire hazard. The lack of approved fire stop materials at these locations also creates a violation of the requirements of 300.21. As is normally the case with these photos, we can also cite this installation for not being done in a neat and workmanlike manner (110.12).
Want to use this article? Click here for options!
© 2012 Penton Media, Inc.
Code Challenge
Code Quiz
May 10, 2012 12:29 PM, By Steven Owen, National Code Seminars
When installing a shielded cable or a twisted pair cable in a Class I, Division 1 location where a cable seal is required, when is it not required to remove the shielding material or separate the twisted pairs of those type cables?...
More Code Quizzes
Code Q&A
May 24, 2012 10:42 AM, By Mike Holt, NEC Consultant
Q. What labeling does the Code require in regard to arc flash hazard warning?...
More Code Q&As
Acceptable Use Policy blog comments powered by Disqus
advertisement
what's wrong here?
What's Wrong Here?
May 10, 2012 12:44 PM
View all What's Wrong Here?
What's Wrong Here
Sponsored By:
product spotlight
EV charger tester
May 25, 2012 8:26 AM
The Electrician is portable tester that verifies critical power and safety requirements of electric vehicle (EV) chargers...
View all 2012 Product Spotlights
Free Product Info
Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.