What’s Wrong Here?, September 2011
Sep 21, 2011 1:43 PM, Joe Tedesco, NEC Consultant
Can you identify the Code violation(s) in this photo?
How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?
Hint: Is this a new type of cable insulation?
‘Tell Them What They’ve Won...’
Using the 2011 NEC, correctly identify the Code sections that show violation(s) in this month’s photo — in 200 words or less — and you could win something to put in your toolbox. E-mail your response to joseph.tedesco@yahoo.com, and we’ll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc., valued at more than $125.* The set includes 9.25-in. insulated side-cutting pliers, 10-in. insulated tongue-and-groove pliers, and a 0.25-in. 3 6-in. insulated screwdriver. (* Please allow six to eight weeks for delivery of tools.)
JULY WINNERS
We had two winners this month: Ray Keith, construction manager, Electric Motor Shop, Fresno, Calif., and Bill Hillebrand, partner GM, Romanoff Electric Louisville, Louisville, Ky. Both men noted a number of violations with this outdoor control station.
The circular opening in the side of the metal enclosure violates the requirements of 110.12(A). Unused openings shall be closed to afford protection equivalent to the wall of the equipment. The same type of requirement is also noted in Sec. 312.5(A) of the Code.
Based on all the dents and scrapes visible on the cover over the enclosure, the proper physical protection of the equipment can be questioned. Speaking of this cover, it appears to be a homemade unit. Maybe the installer was trying to secure a NEMA 3 rating for this installation.
The unprotected flexible cords and cables also violate the requirements of 400.8(7). They are clearly subject to physical damage. In addition, many of the conduits are unsupported.
Lastly, the lack of proper working clearance in front of the disconnect violates the requirements of 110.26.
Want to use this article? Click here for options!
© 2012 Penton Media, Inc.
Code Challenge
Code Quiz
May 10, 2012 12:29 PM, By Steven Owen, National Code Seminars
When installing a shielded cable or a twisted pair cable in a Class I, Division 1 location where a cable seal is required, when is it not required to remove the shielding material or separate the twisted pairs of those type cables?...
More Code Quizzes
Code Q&A
May 24, 2012 10:42 AM, By Mike Holt, NEC Consultant
Q. What labeling does the Code require in regard to arc flash hazard warning?...
More Code Q&As
Acceptable Use Policy blog comments powered by Disqus
advertisement
what's wrong here?
What's Wrong Here?
May 10, 2012 12:44 PM
View all What's Wrong Here?
What's Wrong Here
Sponsored By:
product spotlight
EV charger tester
May 25, 2012 8:26 AM
The Electrician is portable tester that verifies critical power and safety requirements of electric vehicle (EV) chargers...
View all 2012 Product Spotlights
Free Product Info
Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.