What's Wrong Here?
Sep 1, 2009 12:00 PM
Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?
How well do you know the Code? Think you can spot violations the original installer either ignored or couldn't identify? Here's your chance to moonlight as an electrical inspector and second-guess someone else's work from the safety of your living room or office. Can you identify the Code violation(s) in this photo?
Hint: Growing out of control
‘TELL THEM WHAT THEY'VE WON…’
Using the 2008 NEC, correctly identify the Code violation(s) in this month's photo — in 200 words or less — and you could win something to put in your tool-box. E-mail your response to brianjbmcpar@aol.com, and he'll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc., valued at more than $125.* The set includes 9.25-in. insulated side-cutting pliers, 10-in. insulated tongue-and-groove pliers, and a 0.25-in. × 6-in. insulated screwdriver. (* Please allow six to eight weeks for delivery of tools.)
July Winners
Our three winners this month were: Paul Furman, owner of PDF Electric, Pawcatuck, Conn.; Timothy Waldman, electrical code official for the city of Reading, Reading, Pa.; and Mark Sheehan, estimator for JH Electrical Enterprises, Poughkeepsie, N.Y. Here's just a few of the many Code violations these three associated with this mess of a residential service panel.
Installation is not neat and workmanlike [110.12].
Improper electrical connections and terminations (i.e., more than one wire terminated on branch and main breakers) [110.14].
Improper identification of grounded and ungrounded conductors (i.e., white wire being used as ungrounded conductor and red wire being used as grounded conductor) [200.6, 200.7 and 210.5].
Undersized conductors attached to main breaker (i.e., not properly protected) [240.4].
Enclosures for switches and overcurrent devices shall not be used as junction boxes [312.8].
Want to use this article? Click here for options!
© 2010 Penton Media, Inc.
Code Challenge
Code Quiz
Mar 11, 2010 12:45 PM, By Steven Owen
When installing outlet boxes for wall-mounted luminaires, when can you use No. 6 screws to secure the luminaire yoke to a plaster ring?...
More Code Quizzes
Acceptable Use Policy blog comments powered by Disqus
advertisement
what's wrong here?
|
Whats Wrong Here?Mar 11, 2010 12:54 PM |
|
What's Wrong Here?Feb 18, 2010 5:04 PM |
|
What's Wrong Here?Feb 4, 2010 5:06 PM |
View all What's Wrong Here?
What's Wrong Here
Sponsored By:

Email