ECM Buyers' Guide

Code Quiz

Nov 13, 2006 10:00 PM, By Steven Owen


         Subscribe in NewsGator Online   Subscribe in Bloglines     

Q. The wiring of the emergency system in hospitals shall be mechanically protected. Where installed as branch circuits in patient care areas, the installation shall comply with the requirements of 517.13(A) and 517.13(B). Which of the following wiring methods is permitted?

  1. Nonflexible metal raceways, Type MI cable, Schedule 80 rigid nonmetallic conduit. Nonmetallic raceways shall not be used for branch circuits that supply patient care areas.
  2. Where encased in not less than 2 inches of concrete. Schedule 40 nonmetallic conduit, flexible nonmetallic or jacketed metallic raceways, or jacketed metallic cable assemblies listed for installation in concrete. Nonmetallic raceways shall not be used for branch circuits that supply patient care areas.
  3. Listed flexible metal raceways and listed metal sheathed cable assemblies in any of the following: a. Where used in listed prefabricated medical headwalls. b. In listed office furnishings. c. Where fished into existing walls or ceilings, not otherwise accessible and not subject to physical damage. d. Where necessary for flexible connection to equipment.
  4. Flexible power cords of appliances and other utilization equipment connected to the emergency system.
  5. Secondary circuits of Class 2 and Class 3 communication or signaling systems.
A) 1 and 2 only
B) 2 and 3 only
C) 1, 2 and 3 only
D) All of the above

Answer: D The requirements for the mechanical protection of the emergency system shall comply with the rules outlined in 517.30(C)(3), (1) through (5).

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at necexpert@aol.com.


Commenting terms of use blog comments powered by Disqus

Want to use this article? Click here for options!

product of the week

Evaluation Software

December 1, 2008 9:59 AM

Honeywell Power Evaluation Software

View all 2008 Products of the Week

Recent Comments

Follow comments on ecmweb.com




Arc Flash Conferences   Code Change Conferences

Professionals provide answers to your questions.



Do you have any technical paper explaining IBC?

iGard Resistance Grounding Q&A BookletDownload the Resistance Grounding Q&A Booklet
I-Gard
EC&M TV

Retrofit 2-Gang TV Box(TM)

Arlington’s recessed two-gang TV BOX™ for old work allows you to mount LCD and plasma TVs, and other system components flush against the wall.

Listen
"Sizing Gen-Sets: Facts, Hints, and Good Judgment"
Listen
Sponsored By:

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

rss icon

rss

Browse Back Issues

Browse Back Issues