ECM Buyers' Guide

Code Quiz


Code Quiz 

Jun 27, 2007, By Steven Owen

When installing a high-impedance grounded neutral system, for a 480V, 3-phase system, the following question has arisen. Which of the following choices best describes the proper routing for the grounded conductor of the system?...

Code Quiz 

Jun 13, 2007, By Steven Owen

When installing a high-impedance grounded neutral system for a 480V, 3-phase electrical system, the following question arises. Where is the proper location for the grounding impedance (resistor)?...

Code Quiz 

May 29, 2007, By Steven Owen

What is the minimum size and metal thickness required for a junction box constructed of sheet steel, with one 4-inch RMC conduit (per wall) connected on opposite walls of the box (i.e., directly across from one another)?...

Code Quiz 

Nov 27, 2006, By Steven Owen

In a Class 1 location of a spray application (Art. 516) area, portable equipment such as portable electric lamps or other utilization equipment shall be permitted in which of the following situations?...

Code Quiz 

Nov 13, 2006, By Steven Owen

The wiring of the emergency system in hospitals shall be mechanically protected. Where installed as branch circuits in patient care areas, the installation shall comply with the requirements of 517.13(A) and 517.13(B). Which of the following wiring methods is permitted?...

Code Quiz 

Oct 25, 2006, By Steven Owen

What is the proper size overload, and branch-circuit, short-circuit, ground-fault protective device permitted for a hermetic compressor with a nameplate rated-load of 38A, and a branch-circuit selection current of 40A?...

Code Quiz 

Oct 11, 2006, By Steven Owen

What is the proper size branch-circuit, short-circuit, ground-fault protective device required for a hermetic compressor with a nameplate rated load of 38A?...

Code Quiz 

Sep 25, 2006, By Steven Owen

What is the minimum size XHHW insulated feeder conductor permitted for an industrial machine, which consists of the following loads? All terminals are rated at 75°C....

Code Quiz 

Sep 8, 2006, By Steven Owen

What is the maximum allowable ampacity of 12 AWG THHN insulated conductors installed in a strut-type channel raceway that is 1½ inches by 1½ inches?...

Code Quiz 

Aug 28, 2006, By Steven Owen

When installing a new service for a separate building constructed on the top floor of a parking garage, it has been determined that the service conductors will have to be installed in rigid metal conduit (RMC) starting in the vault below grade of the first floor level of the parking garage...

Code Quiz 

Aug 14, 2006, By Steven Owen

What is the maximum number of 12 AWG THHN insulated conductors permitted in a strut-type channel raceway that is 1½ inches by 1½ inches and of unlimited length?...

Code Quiz 

Jul 25, 2006, By Steven Owen

What is the minimum size NM cable required for an electric space-heating branch circuit installed 3 inches above a heated ceiling (with no thermal insulation) in a dwelling unit?...

Code Quiz 

Jul 11, 2006, By Steven Owen

When installing electric heat-tracing cables and heating panels in industrial installations (where ground fault alarm indication is provided and the operation cannot tolerate a ground fault condition that would normally open the circuit overcurrent device)...

Code Quiz 

Jun 20, 2006, By Steven Owen

What is the minimum acceptable voltage at a fire pump motor’s terminals, when the 460V-rated motor is supplied with an operating voltage of 480V, and the motor is operating at 115% of the full-load current rating of the motor?...

Code Quiz 

Jun 12, 2006, By Steven Owen

When installing wiring from a fire pump controller to a fire pump motor, which of the following wiring methods is not permitted?...

Code Quiz 

May 24, 2006, By Steven Owen

An existing corporate data center is concerned about possible loss of power due to the fact that it is supplied by only one service. The existing feed consists of a 1600A, 208Y/120V, 3-phase, four-wire service. Data center management personnel propose to add an additional service....

Code Quiz 

May 11, 2006, By Steven Owen

According to 110.16, certain information is required on the label when marking switchboards, panelboards, industrial control panels, meter socket enclosures, and motor control centers....

Code Quiz 

Apr 24, 2006, By Steven Owen

Excluding exceptions, what is the requirement for cabling work space, which includes a requirement for a clear work space not less than...

Code Quiz 

Apr 11, 2006, By Steven Owen

What is the minimum number of 20A branch circuits required for a guest suite of a hotel or motel, which consists of the following...

Code Quiz 

Mar 26, 2006, By Steven Owen

Disregarding the Exceptions in 225.32, when are you not required to install a disconnecting means for a building or structure at the building or structure?...

Code Quiz Correction 

Mar 12, 2006, By Steven Owen

The answer to the question below, shown in the March 13 issue of CodeWatch, was incorrectly shown as: A) fire alarm systems. In retrospect, I should have added a fifth option, which read as follows: E) none of the above. This would be the correct answer in this case....

Code Quiz 

Feb 26, 2006, By Steven Owen

With respect to a solar photovoltaic system, a disconnecting means is required to disconnect all current-carrying conductors of a photovoltaic power source from all other conductors in a building or other structure. A switch or circuit breaker shall not be installed in a grounded conductor unless...

Previous | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | Next

what's wrong here?

What's Wrong Here?

Feb 2, 2012 7:54 PM

What's Wrong Here?

Jan 19, 2012 4:06 PM

What's Wrong Here?

Jan 5, 2012 11:53 AM

View all What's Wrong Here?

product spotlight

Emergency lighting controls

Feb 9, 2012 8:40 AM

Emergency lighting controls

The UL924 emergency lighting control relay (ERC) mounts in the ceiling and features an automatic diagnostic feature ...

View all 2012 Product Spotlights

Free Product Info

Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.

Recent Comments

More...


Social Media

More ways to stay informed...

follow us on twitter

Find us on Facebook

EC&M TV

Arlington CP9000

Arlington's new 9" diameter ceiling cover plate is the neatest way to cover unused "high hat" cans. With no tools needed, installation couldn't be faster!...

Arlington Gangable Boxes

Designed for new or retrofit applications, these snap-together gangable plastic boxes eliminate the need to construct a multiple-gang steel box out of several individual ones...

Understanding NEC Requirements for Solar Photovoltaic Systems
During this session, Mike Holt will address possible conflicts or confusing NEC requirements, provide tips on proper electrical installation techniques, and discuss the dangers related to improper installations. View this On Demand Webinar!



resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

industry links

industry links

rss icon

rss

Browse Back Issues

Browse Back Issues