Oct 26, 2007 11:44 PM, By Steven Owen


         Subscribe in NewsGator Online   Subscribe in Bloglines     

Q. A new service consisting of 6 individual disconnect switches has been installed outdoors, on the back side of a small retail shopping center. One of the disconnect switches has been installed remote from the others. The disconnect installed remote from the others is for the water pump intended for fire protection. Is this installation NEC compliant?

    1. Yes, because the disconnect switches can be installed in any location and in any grouping of the installers choice — no NEC requirement.
    2. Yes, because one of the two to six service disconnecting means is permitted to be installed remote from the others that are grouped together in one location if it meets the requirements of the exception associated with the grouping requirement.
    3. No, because retail shopping locations require that all service disconnects be installed in a locked room in a separate building adjacent to the shopping area.
    4. No, because all service disconnects need to be installed in indoor locations only.

Answer: B

One of the two to six service disconnecting means is permitted to be installed remote from the others that are grouped together in one location if it meets that requirements of the exception associated with the grouping requirement. [230.72(A)(EX)]

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at necexpert@aol.com.


Acceptable Use Policy
blog comments powered by Disqus

Want to use this article? Click here for options!

what's wrong here?

What's Wrong Here?

Jul 2, 2009 6:51 PM

What's Wrong Here?

Jun 18, 2009 4:01 PM

What's Wrong Here?

Jun 4, 2009 1:26 PM

View all What's Wrong Here?

Recent Comments

Follow comments on ecmweb.com

i-Gard contest
Here’s your chance to win $5000! All you have to do is submit a case history based on your or your client’s experience (positive or negative) in applying HRG technology to an existing or new power distribution system.
EC&M White Papers
Protecting Generators through Hybrid Grounding
The industry has recently become aware of the problem of severe generator damage due to stator ground faults. Two factors have been identified as contributors to this growing problem
EC&M TV

Retrofit 2-Gang TV Box(TM)

Arlington’s recessed two-gang TV BOX™ for old work allows you to mount LCD and plasma TVs, and other system components flush against the wall...

Hybrid Grounding - The industry has recently become aware of the problem of severe generator damage due to stator ground faults. Join us for this live webinar!

Arc Flash HazardThe 3 As of Arc Flash - Awareness, Analysis, Action

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

rss icon

rss

Browse Back Issues

Browse Back Issues