ECM Buyers' Guide

Code Quiz

Jul 13, 2007 2:11 PM, By Steven Owen


         Subscribe in NewsGator Online   Subscribe in Bloglines     

Q. When installing metal-armored cables and metal raceways, is it permissible to connect a metal-armored cable or a metal raceway to a nonmetallic box?

    1. Yes, as long as the armored cable is BX cable or equivalent. There is an internal equipment grounding conductor, however, there is no internal bonding means available to bond the armored cables together.
    2. Yes, as long as the raceway is flexible metal conduit or liquidtite flexible metal conduit installed in a length not to exceed 6 feet. There is no internal equipment grounding conductor or and no bonding means available to bond the cables together.
    3. Yes. Where internal bonding means are provided between all entries, nonmetallic boxes shall be permitted to be used with metal raceways or metal-armored cables.
    4. No way! This is not going to happen according to the rules of the NEC.
Answer: C

As per 314.3, “Nonmetallic boxes shall be permitted only with open wiring on insulator, concealed knob-and-tube wiring, cabled wiring methods with entirely nonmetallic sheaths, flexible cords, and nonmetallic raceways.”

Exception No. 1: Where internal bonding means are provided between all entries, nonmetallic boxes shall be permitted to be used with metal raceways or metal-armored cables.

Exception No. 2: Where integral bonding means with a provision for attaching an equipment bonding jumper inside the box are provided between all threaded entries in nonmetallic boxes listed for the purpose, nonmetallic boxes shall be permitted to be used with metal raceways or metal-armored cables.

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at necexpert@aol.com.


Commenting terms of use blog comments powered by Disqus

Want to use this article? Click here for options!

product of the week

Evaluation Software

December 1, 2008 9:59 AM

Honeywell Power Evaluation Software

View all 2008 Products of the Week

Recent Comments

Follow comments on ecmweb.com




Arc Flash Conferences   Code Change Conferences

Professionals provide answers to your questions.



Do you have any technical paper explaining IBC?

iGard Resistance Grounding Q&A BookletDownload the Resistance Grounding Q&A Booklet
I-Gard
EC&M TV

Retrofit 2-Gang TV Box(TM)

Arlington’s recessed two-gang TV BOX™ for old work allows you to mount LCD and plasma TVs, and other system components flush against the wall.

Listen
"Sizing Gen-Sets: Facts, Hints, and Good Judgment"
Listen
Sponsored By:

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

rss icon

rss

Browse Back Issues

Browse Back Issues