Jun 27, 2007 3:35 PM, By Steven Owen


         Subscribe in NewsGator Online   Subscribe in Bloglines     

Q. When installing a high-impedance grounded neutral system, for a 480V, 3-phase system, the following question has arisen. Which of the following choices best describes the proper routing for the grounded conductor of the system?

    1. It shall be run (installed) in the same raceway with the other phase conductors. This is the only choice. No other options are available.
    2. It shall be run (installed) in a non-metallic raceway with the other phase conductors, following the requirements of 300.5(I)(Exception No. 2).
    3. It shall be permitted to be run (installed) in the same raceway with the other phase conductors if desired; however, it shall also be permitted to be installed in a separate raceway by itself with any routing chosen by the installer.
    4. It must be insulated, bare, or covered, and installed so as not to be easily damaged, with or without a raceway for protection.

Answer: C

As per 250.36(D), “The conductor connecting the neutral point of the transformer or generator to the grounding impedance shall be permitted to be installed in a separate raceway. It shall not be required to run this conductor with the phase conductors to the first system disconnecting means or overcurrent device.”

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at necexpert@aol.com.


Acceptable Use Policy
blog comments powered by Disqus

Want to use this article? Click here for options!

what's wrong here?

What's Wrong Here?

Jul 2, 2009 6:51 PM

What's Wrong Here?

Jun 18, 2009 4:01 PM

What's Wrong Here?

Jun 4, 2009 1:26 PM

View all What's Wrong Here?

Recent Comments

Follow comments on ecmweb.com

i-Gard contest
Here’s your chance to win $5000! All you have to do is submit a case history based on your or your client’s experience (positive or negative) in applying HRG technology to an existing or new power distribution system.
EC&M White Papers
Protecting Generators through Hybrid Grounding
The industry has recently become aware of the problem of severe generator damage due to stator ground faults. Two factors have been identified as contributors to this growing problem
EC&M TV

Retrofit 2-Gang TV Box(TM)

Arlington’s recessed two-gang TV BOX™ for old work allows you to mount LCD and plasma TVs, and other system components flush against the wall...

Hybrid Grounding - The industry has recently become aware of the problem of severe generator damage due to stator ground faults. Join us for this live webinar!

Arc Flash HazardThe 3 As of Arc Flash - Awareness, Analysis, Action

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

rss icon

rss

Browse Back Issues

Browse Back Issues