Code Quiz
Q. When connecting a surge protective device (SPD) grounding conductor of a Type 1 SPD at the service, which of the following connections is permitted? Note: the SPD may be a surge arrester or TVSS.
- Equipment grounding terminal in the service equipment.
- Grounding electrode for the service.
- Grounding electrode conductor.
- Grounded service conductor
- All of the above are permitted.
Answer: E
As per 285.23(B) of the 2008 NEC, any of the above mentioned methods are considered an acceptable installation.
Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at necexpert@aol.com.
Want to use this article? Click here for options!
© 2012 Penton Business Media, Inc.
Latest Articles
Labeling tool
Feb 10, 2012 7:58 AM
Emergency lighting controls
Feb 9, 2012 8:40 AM
Cupertino Electric Sponsors Construction Industry Academic Competition
Feb 8, 2012 4:14 PM
Trending Articles
Acceptable Use Policy blog comments powered by Disqus
advertisement
product spotlight
Labeling tool
Feb 10, 2012 7:58 AM
The Rhino 4200 labeling tool features one-touch “hot keys” that quickly create and format wire/cable wraps, flags, fixed-length labels and more...
View all 2012 Product Spotlights
Free Product Info
Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.



































