Code Q&A 

Dec 17, 2009, By Mike Holt

Q. Are AFCIs required for light fixtures and smoke alarms?...

Code Q&A 

Dec 3, 2009, By Mike Holt

Q. I recently saw a service disconnect that was being used as a conduit for two feeder circuits. Is this legal?...

Code Q&A 

Nov 19, 2009, By Mike Holt

Q. I need to run a feeder to a pool house panel. What are the wiring methods required for this type of installation?...

Code Q&A 

Nov 5, 2009, By Mike Holt

When are tamper-resistant receptacles required?...

Code Quandaries 

Nov 1, 2009, By Mike Holt, NEC Consultant

Q. Is it legal to splice conductors in an "LB" fitting?...

Code Q&A 

Oct 22, 2009, By Mike Holt

Q. Can I install a panel in the clothes closet of a house if the working space of 110.26 is maintained?...

Code Q&A 

Oct 8, 2009, By Mike Holt

Q. We do a lot of generators for residences, and only recently have been getting written up on our transfer switches. The inspectors are saying that if I use the transfer switch to transfer the entire house — and I put it between the meter and the service disconnect — then the transfer switch must be 'service rated.' Can you help me understand the rules, please?...

Code Quandaries 

Oct 1, 2009, By Mike Holt, NEC Consultant

For a 240V to 208Y/120V transformer, is it better to bond the neutral to the metal frame at the transformer itself, at the panel, or at both locations?...

Code Q&A 

Sep 24, 2009, By Mike Holt

Q. What is the maximum length of raceway I can use where the conductor ampacity is not required to be adjusted for conductor bundling?...

Code Q&A 

Sep 10, 2009, By Mike Holt, NEC Consultant

Q. We have a heat tape system installed on a metal roof. Someone told us to use a GFCI on the circuit, and someone else told us not to. Does the NEC offer any guidance here?...

Stumped by the Code? 

Sep 9, 2009, By Mike Holt, NEC Consultant

Q. Do we have to install a receptacle behind the swing of a door in a bedroom of a dwelling unit, even if the wall is only 2 ft 6 in. wide?...

Code Quandaries 

Sep 1, 2009, By Mike Holt, NEC Consultant

Q. What are the NEC grounding requirements for satellite dishes?...

Code Q&A 

Aug 20, 2009, By Mike Holt

Q. What are the GFCI requirements for vending machines?...

Code Q&A 

Aug 6, 2009, By Mike Holt

Q. Can we use EMT in a masonry wall, or must we use RMC?...

Code Q&A 

Jul 16, 2009, 

Q. Can we install a 3-wire feeder (no equipment ground) to a pool house and bond the neutral and ground at the new panel?...

Code Q&A 

Jul 2, 2009, By Mike Holt

Q. Is the grounding conductor for a TV antenna sized the same as a grounding conductor for a satellite dish?...

Code Quandaries 

Jul 1, 2009, By Mike Holt, NEC Consultant

Q. I am having a hard time understanding the rule on how to size the circuit breaker/fuse for a motor that has separate overload protection. Can you please explain this rule?...

Code Q&A 

Jun 18, 2009, By Mike Holt

Q. Do we still have to bond the deck of an outdoor swimming pool if the deck is constructed of pavers?...

Code Q&A 

Jun 4, 2009, By Mike Holt

Q. We are being told that we must GFCI protect our receptacle for the washing machine if it is located within 6 ft of the laundry sink....

Code Quandaries 

Jun 1, 2009, By Mike Holt, NEC Consultant

Q. I am having a hard time understanding the feeder tap rules. Can you please show an example of how the 1/10 rule for 10-ft taps applies?...

Code Q&A 

May 21, 2009, By Mike Holt

Q. What are the requirements for grounding metal equipment racks supporting computer servers?...

Code Q&A 

May 7, 2009, By Mike Holt

Q. We are being told that we can’t use PVC conduit underground to provide power to the gasoline pumps we are wiring. Is this true?...

Code Quandaries 

May 1, 2009, By Mike Holt, NEC Consultant

Q. How does the Code address diesel fuel dispensers as they relate to hazardous locations? ...

Code Q&A 

Apr 23, 2009, By Mike Holt

Q. I am hearing differing opinions about the requirements for bonding steel gas piping. What are the rules for this?...

Code Q&A 

Apr 9, 2009, By Mike Holt

Q. The old panels in an industrial building do not have complete panel schedules. Does the Code require us to update them?...

Previous | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | Next

what's wrong here?

What's Wrong Here?

Feb 2, 2012 7:54 PM

What's Wrong Here?

Jan 19, 2012 4:06 PM

What's Wrong Here?

Jan 5, 2012 11:53 AM

View all What's Wrong Here?

product spotlight

Emergency lighting controls

Feb 9, 2012 8:40 AM

Emergency lighting controls

The UL924 emergency lighting control relay (ERC) mounts in the ceiling and features an automatic diagnostic feature ...

View all 2012 Product Spotlights

Free Product Info

Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.

Recent Comments

More...


Social Media

More ways to stay informed...

follow us on twitter

Find us on Facebook

EC&M TV

Arlington CP9000

Arlington's new 9" diameter ceiling cover plate is the neatest way to cover unused "high hat" cans. With no tools needed, installation couldn't be faster!...

Arlington Gangable Boxes

Designed for new or retrofit applications, these snap-together gangable plastic boxes eliminate the need to construct a multiple-gang steel box out of several individual ones...

Understanding NEC Requirements for Solar Photovoltaic Systems
During this session, Mike Holt will address possible conflicts or confusing NEC requirements, provide tips on proper electrical installation techniques, and discuss the dangers related to improper installations. View this On Demand Webinar!



resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

industry links

industry links

rss icon

rss

Browse Back Issues

Browse Back Issues