ECM Buyers' Guide

Code Q&A


Code Q&A 

Sep 27, 2007, By Mike Holt

Q. A conductor passing through a box unbroken counts as one conductor, so if I loop a conductor through the box unbroken and strip off enough insulation to terminate on a receptacle without cutting the wire, does the conductor count as one or two conductors for box sizing?...

Code Q&A 

Sep 13, 2007, By Mike Holt

Q. I want to install fluorescent strip lights on a sheetrock ceiling. Can I support the fixtures directly over the recessed outlet box and connect to the branch-circuit wiring through a chase nipple?...

Code Q&A 

Aug 27, 2007, By Mike Holt

Q. What is the minimum service drop clearance above a roof?...

Code Q&A 

Aug 13, 2007, By Mike Holt

Q. Can I use aluminum rigid metal conduit in a Class 1, Div. I hazardous (classified) location?...

Code Q&A 

Jul 27, 2007, By Mike Holt

Q. Can the disconnect switch be located next to equipment installed above an accessible drop ceiling, or must the switch be installed at a readily accessible location?...

Code Q&A 

Jul 13, 2007, By Mike Holt

Q. In a dwelling unit, what are the receptacle requirements for island counter tops?...

Code Quandaries 

Jul 1, 2007, By Mike Holt, NEC Consultant

Q. Can I pass conductors from one panel through another panel? If so, what are the restrictions?...

Code Q&A 

Jun 27, 2007, By Mike Holt

Q. What are the requirements for supporting outlet boxes above/to suspended ceilings?...

Code Q&A 

Jun 13, 2007, By Mike Holt

Q. When a lighting and appliance panelboard is fed from the secondary of a 3-phase transformer, is the panelboard required to have a main breaker installed in it?...

Code Q&A 

May 29, 2007, By Mike Holt

Q. Can I install conductors from different panels in the same raceway?...

Stumped by the Code? 

Apr 1, 2007, By Mike Holt, NEC Consultant

Q. Is it legal to make a mechanical transition from electrical metallic tubing (EMT) to flexible metal conduit with a fitting that joins these two raceways instead of installing a box?...

Stumped by the Code? 

Feb 1, 2007, By Mike Holt, NEC Consultant

Q. Can I ground a satellite system to the metal parts of electrical equipment?...

Stumped by the Code? 

Dec 1, 2006, By Mike Holt, NEC Consultant

Q. Do I need to use hospital-grade receptacles in a chiropractor's or medical examining room?...

Code Q&A 

Nov 27, 2006, By Mike Holt

Q. What are the limitations on the use of rigid nonmetallic conduit in an underground application serving a gasoline dispenser?...

Code Q&A 

Nov 13, 2006, By Mike Holt

Q. Can Table 310.15(B)(6) (reduced size wire for dwelling unit service) be used to size the service neutral conductor for a single-family dwelling?...

Stumped by the Code? 

Nov 1, 2006, By Mike Holt, NEC Consultant

Q. How far away must I locate a receptacle outlet from a shower or bathtub?...

Code Q&A 

Oct 25, 2006, By Mike Holt

Q. Do I have to use bonding jumpers around listed reducing washers?...

Code Q&A 

Oct 11, 2006, By Mike Holt

Q. If an outdoor generator has a disconnect, do I need an additional disconnect where the conductors enter the building?...

Code Q&A 

Sep 25, 2006, By Mike Holt

Q. Can I use 12-3 NM cable to wire the bathroom GFCIs and laundry circuit in a dwelling?...

Code Q&A 

Sep 8, 2006, By Mike Holt

Q. I recently saw an advertisement for red conduit that is to be used for emergency circuits. Is this a Code requirement?...

Code Quandaries 

Sep 1, 2006, By Mike Holt, NEC Consultant

Q. What size conductor is required for a 25-hp, 208V, 3-phase fire pump motor?...

Code Q&A 

Aug 28, 2006, By Mike Holt

Q. Can “line” and “load” conductors be installed in the same raceway?...

Code Q&A 

Aug 14, 2006, By Mike Holt

Q. What type of fitting can I use to terminate ground wires in a metal box?...

Stumped by the Code? 

Aug 1, 2006, By Mike Holt, NEC Consultant

Q. Can 277V circuit conductors be placed within the same raceway with 120V circuit conductors?...

Code Q&A 

Jul 25, 2006, By Mike Holt

Q. Is liquidtight flexible metal conduit (LFMC) permitted under the raised floor of a computer room? If yes, must it be secured?...

Previous | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | Next

what's wrong here?

What's Wrong Here?

Nov 5, 2009 11:50 AM

What's Wrong Here?

Oct 22, 2009 11:16 PM

What's Wrong Here?

Oct 8, 2009 3:32 PM

View all What's Wrong Here?

product of the week

Video camera scopes

November 16, 2009

Video camera scopes

View all 2009 Products of the Week

Recent Comments

More...


EC&M TV

Exterior Fixture Box for Brick or Stone

Installing a fixture box in a brick or stone wall just got easier with Arlington’s new adjustable depth box!

Southwire's 2009 Cable Innovation Road Show

Gain years worth of insight in only 2-1/2 hours with Southwire’s 2009 Cable Innovation Road Show with Grounding Seminar. The agenda is packed with valuable information that focuses on installation tips!

Listen
Sizing Gen-Sets: Facts, Hints, and Good Judgment
Listen

The complexities of today’s commercial or industrial facility, with their equipment environment of linear and nonlinear loads, places a whole new light on sizing engine-generator sets.

Arc Mitigation - A Total System Approach
There’s no question the risk of arc flash hazards is real in the electrical industry. What many don’t always realize is the impact in business interruption from such events typically far outweighs the physical damage to equipment. View this On Demand Webinar!

Implementing an Industrial Ethernet Infrastructure that's Built to Last
This webinar explores the key benefits of implementing a robust complete, end-to-end Industrial Ethernet solution – from cabling and connectivity, to active components and associated hardware. View this On Demand Webinar!

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

rss icon

rss

Browse Back Issues

Browse Back Issues