Bottleneck Motor Repairs, Part 6
Mar 24, 2009 3:17 PM
It seems obvious that troubleshooting guides and repair procedures can shorten the downtime of critical equipment (including bottleneck motors). Maintenance departments typically produce such guides and procedures for this reason. Two other reasons include:
- ISO9001/9002/9003 certification. This is about standardization, not reducing downtime.
- Reducing the required skill level. This usually produces unintended negative consequences.
What has dominated is a tendency to overdo the documentation. Guides and procedures become so bloated that people either don’t understand them or refuse to read them in the first place. Simply limiting the page count means the same information gets crammed into the page in tiny type that’s hard to read even with a magnifying glass. The problem is the content, not the number of pages. These documents are often so dense with boilerplate, explanations, and minutiae that maintenance techs find them useless.
Ensure your documents are:
- Summarizing. Provide an "outline" of what needs to be done. Qualified personnel need the major steps identified, not described in great detail.
- Focused. Don’t include anything that doesn’t directly serve getting the job done. Less is more.
- Clear. Use short sentences. Express steps in the verb-noun format (e.g., "Disconnect power"). Excess wording tends to confuse instead of clarify.
- Precise. Use few words, chosen carefully — not more words to explain what you meant.
Want to use this article? Click here for options!
© 2009 Penton Business Media, Inc.
MRO Insider
Safety
Nov 10, 2009 12:11 PM
Hardhats originally were developed to protect a person's head from falling rivets and other small objects that could injure an unprotected head...
NEC in the Facility
Nov 10, 2009 12:09 PM
Keep service conductors separate from other conductors and systems. Two primary rules apply...
Electrical Troubleshooting Quiz
Nov 10, 2009 12:06 PM
Several years ago, your facility completed a major project that converted plant data systems, such as statistical process control (SPC), from hard-wired Ethernet to wireless...
Maintaining Your Service Entrance, Part 3
Nov 10, 2009 12:04 PM
Many tasks essential to proper maintenance of service equipment require de-energization. To perform those tasks, you must schedule an outage...
Acceptable Use Policy blog comments powered by Disqus
advertisement
what's wrong here?
|
What's Wrong Here?Nov 5, 2009 11:50 AM |
|
What's Wrong Here?Oct 22, 2009 11:16 PM |
|
What's Wrong Here?Oct 8, 2009 3:32 PM |
View all What's Wrong Here?
What's Wrong Here
Sponsored By: