What's Wrong Here?

Feb 1, 2008 12:00 PM, By Joe Tedesco, NEC Columnist

Can you spot the Code violations?


         Subscribe in NewsGator Online   Subscribe in Bloglines     

How well do you know the Code? Think you can spot violations the original installer either ignored or couldn't identify? Here's your chance to moonlight as an electrical inspector and second-guess someone else's work from the safety of your living room or office. Joe Tedesco, who has a knack for finding shoddy electrical work, did the dirty work and found this mess. Now it's your turn to identify the violation.

Hint: Watch your step.



December Winners

Our three winners this month (Kevin Rick, president and supervising electrician, Rick Electrical Contractors, Inc., Sugar Grove, Ill.; Josh Schroeder, electrical engineer, MBN Engineering, Fargo, N.D.; and Marek Tenerowicz, controls engineer, OFS, Sturbridge, Mass.) all cited most of the same violations with regard to the December photo. Here's a sampling of their findings along with the appropriate 2005 Code reference.

“The missing meter socket panelboard covers, conduit not being securely supported/connected, debris inside of cabinets and surrounding electrical area, and the exposed tangled nest of conductors are clearly not installed in a neat and workmanlike manner [110.12]. In addition, the cabinets, meter socket enclosures and gutters are not effectively closed since they are missing covers. [110.12(A)]

“It appears that there is some type of foreign material or garbage (white) inside the bottom of the second cabinet from the left-hand side. The gutter also contains a corrosive residue on its perimeter opening where the cover should be installed. This violates 110.12(C) and 300.6(A).

“The conduit or raceway on the far left-hand side cabinet is not firmly secured to the surface on which it is mounted. [110.13(A)]

“The gutter is not a completely secured system due to the missing cover. [366.100]

“The conduit on the far left hand side is not connected to the cabinet, which means it's not electrically continuous [300.10], mechanically secured [300.11], or mechanically continuous [300.12].

“The loose raceway/conduit in free air on the far right-hand cabinet is not securely connected to the meter socket cabinet. Therefore, this raceway/conduit does not have any means of bonding to the cabinet/meter socket. [250.90]

“It appears the white conduit connected to the second meter socket cabinet on the right hand side is plumbing PVC and not rigid nonmetallic conduit (RNC). Plumbing PVC is not recognized as an electrical raceway for use in electrical installations. [352.120]”



‘TELL THEM WHAT THEY'VE WON…’

Correctly identify the Code violation(s) in this month's photo — in 200 words or less — and you could win something to put in your toolbox. E-mail your response to Joe Tedesco at joetedesco@comcast.net, and he'll select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Winners will receive a set of insulated hand tools from Ideal Industries, Inc. valued at more than $125.* The set includes 9.25-inch insulated side-cutting pliers, 10-inch insulated tongue-and-groove pliers, and a 0.25-inch × 6-inch insulated screwdriver.

* Please allow six to eight weeks for delivery of tools.


Acceptable Use Policy
blog comments powered by Disqus

Want to use this article? Click here for options!

what's wrong here?

What's Wrong Here?

Jul 2, 2009 6:51 PM

What's Wrong Here?

Jun 18, 2009 4:01 PM

What's Wrong Here?

Jun 4, 2009 1:26 PM

View all What's Wrong Here?

Recent Comments

Follow comments on ecmweb.com

i-Gard contest
Here’s your chance to win $5000! All you have to do is submit a case history based on your or your client’s experience (positive or negative) in applying HRG technology to an existing or new power distribution system.
EC&M White Papers
Protecting Generators through Hybrid Grounding
The industry has recently become aware of the problem of severe generator damage due to stator ground faults. Two factors have been identified as contributors to this growing problem
EC&M TV

Retrofit 2-Gang TV Box(TM)

Arlington’s recessed two-gang TV BOX™ for old work allows you to mount LCD and plasma TVs, and other system components flush against the wall...

Hybrid Grounding - The industry has recently become aware of the problem of severe generator damage due to stator ground faults. Join us for this live webinar!

Arc Flash HazardThe 3 As of Arc Flash - Awareness, Analysis, Action

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

rss icon

rss

Browse Back Issues

Browse Back Issues