Electrical contractors no longer need to pull extra cable to meet the NEC's requirement for AFCI circuits in bedrooms. Southwire's Romex NM-B four-conductor non-metallic cable simplifies two-circuit wiring and reduces installation costs.


“Over the years, local codes have been developed in certain areas of the country that require separate circuits for bedrooms,” says David Mercier, technical director for Southwire's electrical division. “Our product allows the contractor to run back-to-back bedroom circuits while simplifying installation.”

The cable's second neutral can be reidentified, making it suitable for multi-circuit applications, such as three-function bathroom fans. The cable has also been used for whirlpool baths, ceiling and fan lights, and kitchen disposals and dishwashers. The NEC requires bedrooms to be equipped with AFCI breakers to protect a home against fire damage caused by faults in the electrical system. Southwire introduced the Type NM-B 2/2 cable to help contractors comply with the Code without changing their wiring practices.

“We had a distributor come to us on behalf of a contractor stating that with the new AFCI requirements he could no longer share a neutral on a three-conductor cable,” Mercier says. “He still wanted to make one cable pull to a bedroom rather than two, so we came up with a solution.”

After determining that the contractor's problem wasn't an isolated case, Southwire began developing a new product. The company made slight modifications to its existing cable and launched the new product as Romex Extra Circuit in May 2002. The manufacturer replaced the blue conductor in the standard four-conductor cable with a white neutral with a red stripe, making it possible to install the product in not only bedrooms, but bathrooms as well. Like many of Romex's other products, the cable is color-coded to ease identification and installation.

“We have received a very good response,” Mercier says. “Contractors who were originally using shared neutrals are excited about having a solution that does not require them to pull two cables. Plus those contractors who were not previously using shared neutrals have embraced this product due to the labor savings it provides.”




PRODUCT SPECS

Applications
This non-metallic sheathed cable may be used for exposed and concealed work in normally dry locations no warmer than 90° C. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. The 600V rated cable may be run in air voids of masonry block or tile walls where such walls aren't subject to excessive moisture or dampness.

Specifications


The cable meets or exceeds UL standards 83 and 719, Federal Specification A-A-59544, and the requirements of the NEC.

Construction


It's manufactured as 2-, 3-, or 4-conductor cable with a ground wire. Copper conductors are soft copper. Stranded conductors are arrow-straight. Conductor installation is 90° C rated polyvinyl chloride (PVC), nylon jacketed. The cable jacket is color-coded for size identification: 14 AWG — White, 12 AWG — Yellow, 10 AWG — Orange, and 8 AWG and 6 AWG — Black.


Want to use this article? Click here for options!





Acceptable Use Policy
blog comments powered by Disqus

what's wrong here?

What's Wrong Here?

May 10, 2012 12:44 PM

What's Wrong Here?

Apr 19, 2012 10:09 AM

What's Wrong Here?

Apr 5, 2012 2:27 PM

View all What's Wrong Here?

product spotlight

EV charger tester

May 25, 2012 8:26 AM

EV charger tester

The Electrician is portable tester that verifies critical power and safety requirements of electric vehicle (EV) chargers...

View all 2012 Product Spotlights

Free Product Info

Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.

Recent Comments

More...


Social Media

More ways to stay informed...

follow us on twitter

Find us on Facebook

EC&M Whitepaper

Arc Mitigation –A Three-Step Approach

Did you know that an arc-flash incident hospitalizes 5-7 workers per day in North America, severely impacting processes and profitability with lost production? Download This Sponsored Whitepaper Today!

What's New in Residential Cabling?
Date: Wednesday, May 30, 2012
Time: 2:00pm ET


In this The Home Depot sponsored Low Voltage Webinar, Ron Kipper RCDD / NTS will discuss the need for compression style coaxial connectors and the migration of the entire CATV, Satellite and Audio / Video industry to them. Register Today!

Grounding Versus Bonding
Now Available On-Demand


In this 60-minute FREE webinar, Mike Holt of Mike Holt Enterprises, Inc. will explain the purpose of grounding and bonding as related to the most current requirements set forth in the 2011 NEC. Register to View On-Demand!

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

industry links

industry links

rss icon

rss

Browse Back Issues

Browse Back Issues