Quizzes on the Code


Choose the best answer:

  1. An additional disconnecting means isn't required on or at the building or structure for the generator feeder conductors when an outdoor-housed generator supplying emergency circuits is equipped with a readily accessible disconnecting means that's located within sight of the building or structure supplied.
    (a) true
    (b) false

  2. Where an outdoor-housed generator supplying legally required circuits is equipped with a readily accessible disconnecting means located within sight of the building or structure supplied, an additional disconnecting means isn't required on or at the building or structure for the generator feeder conductors.
    (a) true
    (b) false

  3. Where acceptable to the authority having jurisdiction (AHJ), connections ahead of and not within the same cabinet, enclosure, or vertical switchboard section as the service disconnecting means are permitted for _____ standby service.
    (a) emergency
    (b) legally required
    (c) optional
    (d) all of these

  4. Art. 702 applies to _____ generators.
    (a) fixed
    (b) portable
    (c) a and b
    (d) none of these

  5. A transfer switch is required for all fixed or portable optional standby power systems for buildings or structures for which an electric-utility supply is either the normal or standby source.
    (a) true
    (b) false

  6. If the transfer switch for a portable generator switches the _____ conductor, then the portable generator must be grounded in accordance with 250.30.
    (a) phase
    (b) equipment grounding
    (c) grounded (neutral)
    (d) all of these

  7. If the transfer switch for a portable generator doesn't switch the _____ conductor, then the equipment-grounding conductor must be bonded to the system-grounding electrode.
    (a) phase
    (b) equipment grounding
    (c) grounded (neutral)
    (d) all of these



Answers and Discussion

  1. (a), true. The new wording in 700.12(B)(6) clarifies that a disconnect for the feeder from a generator isn't required at or on the building or structure if the emergency generator disconnecting means is within sight of the building or structure. See Art. 100 for the definition of “in sight.”

  2. (a), true. The new wording in 701.11(B)(5) clarifies that a disconnect for the feeder from a generator isn't required at or on the building or structure if the emergency generator disconnecting means is within sight of the building or structure. See Art. 100 for the definition of “in sight.”

  3. (b), legally required. The revised wording in 701.11(E) clarifies that where acceptable to the AHJ, connections ahead of and not within the same cabinet, enclosure, or vertical switchboard section with the service disconnecting means may supply legally required standby power.

  4. (c), a and b. A new sentence in 702.1 clarifies that Art. 702 applies to portable generators, which are commonly used for telecommunications facilities, water and waste water pump stations, and backup power to homes and offices.

  5. (a), true. The Code now requires a transfer switch whenever a fixed or portable standby generator is connected to premises wiring (702.6).

  6. (c), grounded (neutral). This means that the neutral of the portable generator must be bonded to the generator case and grounding electrode in accordance with 250.30 [702.10(A)].

  7. (c), grounded (neutral). This means that the grounded (neutral) conductors of the generator may not be bonded to the case (250.142), but the case must be bonded to a system-grounding electrode. However, the grounding electrode system for the building can be used for this purpose [702.10(B)].

Are you still confused by the Code? For additional information on Code-related topics please visit www.mikeholt.com or send an e-mail directly to the author at mike@mikeholt.com.






Acceptable Use Policy
blog comments powered by Disqus

what's wrong here?

What's Wrong Here?

May 10, 2012 12:44 PM

What's Wrong Here?

Apr 19, 2012 10:09 AM

What's Wrong Here?

Apr 5, 2012 2:27 PM

View all What's Wrong Here?

product spotlight

EV charger tester

May 25, 2012 8:26 AM

EV charger tester

The Electrician is portable tester that verifies critical power and safety requirements of electric vehicle (EV) chargers...

View all 2012 Product Spotlights

Free Product Info

Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.

Recent Comments

More...


Social Media

More ways to stay informed...

follow us on twitter

Find us on Facebook

EC&M Whitepaper

Arc Mitigation –A Three-Step Approach

Did you know that an arc-flash incident hospitalizes 5-7 workers per day in North America, severely impacting processes and profitability with lost production? Download This Sponsored Whitepaper Today!

What's New in Residential Cabling?
Date: Wednesday, May 30, 2012
Time: 2:00pm ET


In this The Home Depot sponsored Low Voltage Webinar, Ron Kipper RCDD / NTS will discuss the need for compression style coaxial connectors and the migration of the entire CATV, Satellite and Audio / Video industry to them. Register Today!

Grounding Versus Bonding
Now Available On-Demand


In this 60-minute FREE webinar, Mike Holt of Mike Holt Enterprises, Inc. will explain the purpose of grounding and bonding as related to the most current requirements set forth in the 2011 NEC. Register to View On-Demand!

resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

industry links

industry links

rss icon

rss

Browse Back Issues

Browse Back Issues