Lighting Changes May Have Benefited Health in Senior Care Facility

Sept. 15, 2016
ACC staff documented a number of important health-related benefits that may have been attributable, at least in part, to the lighting changes.

DOE's GATEWAY program has released a new report on a pilot installation of tunable-white LED systems at a senior-care facility. The project was coordinated by the Sacramento Municipal Utility District (SMUD), which worked with ACC Care Center, a senior senior in Sacramento, Calif., to establish goals that included learning more about how tunable-white lighting affects the sleep patterns, nighttime safety, and other behaviors of the residents; and better equipping the staff to provide excellent care by improving the quality of lighting (e.g., reduced glare, better controllability) relative to the incumbent system.

DOE's role in the project was to take pre- and post-installation field measurements of illuminance and color quality, advise SMUD on what equipment to specify, and compare the energy consumption of the new system with that of the old one. The lighting solutions followed guidelines published by the Lighting Research Center of Rensselaer Polytechnic Institute, which are based on the role light is believed to play in suppressing the release of melatonin, a hormone that helps control the sleep-wake cycle. Disturbed sleep patterns are common among the residents of senior-care facilities.

Several different tunable-white LED systems were chosen and installed in one corridor, two resident rooms, the nurse station, the common family room, and the administrator's office. The incumbent fluorescent systems were evaluated in August 2015 and the trial LED systems in December 2015.

The illuminance levels in the resident rooms and bathrooms did not meet current industry standards with the incumbent fluorescent system, but exceeded Illuminating Engineering Society recommendations for the over-65 age group with the LED system. Color consistency for the tunable LED luminaires used in the corridors, nurse station, family room, and administrator's office was very good between luminaires and over the dimming range. Energy savings for the tunable LED luminaires in the corridors was 45% relative to the fluorescent system, based on the reduced power, but those savings increased to 68% when the automatic dimming was considered.

ACC staff documented a number of important health-related benefits that may have been attributable, at least in part, to the lighting changes. For example, among the three residents studied, agitated behaviors such as yelling and crying decreased following the LED trial installation. In addition, psychotropic and sleep medications were significantly reduced for one of the residents. And in the corridor studied, the number of patient falls recorded decreased after the LED installation.

Among the lessons learned from the project were that contractors aren't yet familiar with tunable systems and controls, that finding the proper balance of automatic versus manual tuning of the lighting spectrum and intensity is challenging, and that educating residents and staff is essential when implementing new lighting solutions in senior-care facilities.

View the Full Report

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Don't Let Burn-Through Threaten Another Data Center or Utility Project

Get the No Burn-Through Elbow eGuide to learn many reasons why Champion Fiberglass elbows will enhance your data center and utility projects today.

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.