Everyone makes mistakes. Some are just funnier than others.

Riding the Light Wave

As our company began work one night on installing a new fire alarm system in the office area of a manufacturing facility, I stepped from a six-foot step ladder onto the top of an eight-foot cubicle partition. To steady myself, I put my hand on one of the two-lamp fluorescent fixtures that was hanging above the office area on chains. The chains must not have been anchored into the ceiling very well because the one I was holding broke free under my weight…and so did every other one in the 100-foot line of lights, one after the other. From my angle it looked like a wave of fixtures laying down gently and in a straight line on the floor. Luckily for me, it so happened this particular line didn't cross any partitions, and the fixtures were only slightly damaged as they fell. After waking up someone from the local electric supply warehouse at 2 a.m. for lamps, we brought in a batch of rolling scaffolds and were able to make things right before the first shift arrived at 7 a.m.Herman Bolton
Asheboro, N.C.




Wire Wound Up

One of the first large jobs I got to run involved pulling four 500 MCM cables and a 1/0 AWG ground into four-inch rigid steel conduit that we'd installed over the course of a three-week job. We used the entire morning to lay out the cable in a zigzag pattern, set up the puller, and plan who would be where during the pull. I even took a little time to school the apprentices on proper make up and how to stagger the cables as they went into the sock. By early afternoon we had about one-third of the cable in the pipe and all was going well when I walked to the feed side of the pull and noticed one of the cables wasn't being used up like the other three. I immediately stopped the pull. It turned out someone had mislabeled one of the other cables and fed both ends into two different conduit openings. Suffice it to say, 500 MCM comes out of four-inch conduit a lot tougher than it goes in.Darryl Cotton
San Diego

Illustrations by Clint Metcalf

About the Author

EC&M Staff

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.