The Art of Selection

Oct. 1, 2007
On the surface, incorporating the concepts of selective coordination in the design of power distribution systems seems like a Why wouldn't you want to design a system that localizes an overcurrent condition and restricts the outage to the affected circuit or piece of equipment? We all know how much we've come to rely on 24/7 power in our homes and, more importantly, in our places of business. The

On the surface, incorporating the concepts of selective coordination in the design of power distribution systems seems like a “no-brainer.” Why wouldn't you want to design a system that localizes an overcurrent condition and restricts the outage to the affected circuit or piece of equipment? We all know how much we've come to rely on 24/7 power in our homes and, more importantly, in our places of business. The entire loss of power in a high-rise condo, large office building, industrial plant, or hospital building is simply unacceptable in today's fast-paced “always-on” world.

But should the concepts of selective coordination be applied to emergency and standby systems too? Are there valid safety risks at play that should require us to incorporate these concepts into our electrical designs? More importantly, should these perceived safety risks merit specific Code requirements as set forth in the NEC? According to the 2008 NEC, the answer remains yes. However, there are those in the industry who disagree — and continue efforts to try and reverse the decision to make this a national mandate.

As an engineer, I tend to agree with their arguments, and wonder why the NEC must mandate the issue of selective coordination for emergency and standby systems. Incorporating these concepts into the design of these types of power systems can be very difficult to achieve, not to mention very costly to implement. Where's the background data that shows this is an issue that affects public safety?

As far as I know, NFPA 110, “Standard for Emergency and Standby Power Systems,” and IEEE Standard 242, “Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems,” both recognize selective coordination as a design consideration, not as a requirement. So why not leave this decision in the hands of the professional engineer until proven data clearly shows this to be an issue of public safety?

To learn more about this controversial issue, turn to the cover story on page 42 and take a look at what Staff Writer Beck Ireland dug up on this topic when speaking with some savvy engineers and Code specialists who are trying to work these requirements into their new designs. The information she presents on how some states and local jurisdictions are allowing exceptions to these requirements is quite interesting.

Do you agree with these exceptions, or do you feel the NEC should continue to mandate selective coordination for emergency and standby systems? I'm very interested in your feedback on this important topic. Please shoot me a quick e-mail at [email protected], and tell me what you think.

About the Author

Michael Eby

Mike received a B.S. degree in electrical engineering in 1986 and an M.S. degree in engineering management in 1994 from the University of South Florida. He is currently a member of the National Fire Protection Association (NFPA), Institute of Electrical and Electronics Engineers (IEEE), Association of Energy Engineers (AEE), and American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE).

Prior to joining EC&M as Editor-in-Chief in September 1999, Mike served as the Executive Editor of Transmission & Distribution World magazine for five years. He currently serves as the Senior Director of Content - Buildings Group in the Infrastructure & Intelligence Division at Informa. Before joining Informa, Mike held various engineering titles within the Substation and Transmission Engineering Groups at Florida Power & Light Co., Juno Beach, FL.

Mike was awarded the Southeastern Electric Exchange (SEE) Excellence in Engineering Award in 1993 and has received numerous regional and national editorial awards for his reporting and writing work in the electrical market.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Don't Let Burn-Through Threaten Another Data Center or Utility Project

Get the No Burn-Through Elbow eGuide to learn many reasons why Champion Fiberglass elbows will enhance your data center and utility projects today.

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.