Simple Solutions Turn Complex on Large Sites

Trying to make changes in a plant that serves a large and changing network of buildings can result in multiple headaches. One mail order prescription company's attempt to provide more power to one of its locations led electrical contractors down a path with many twists. When Express Scripts, Maryland Heights, Mo., needed to increase power to an area being converted into a print center, the company contracted Bell Electrical Contractors, Maryland Heights, Mo., for the job.

“This project seemed pretty straightforward at first. It was just a situation where we needed to increase the service size,” says Tom Barker, a project manager with Bell. “It was a 480/277V 3-phase 4-wire service, 200A. We needed to increase it to 400A. We just needed to install a second panel, and it would be done in parallel.”

Barker and his crew needed to install the new panel 200 ft from the meter, and because the building housed other tenants, the conduit from the panel to the meter couldn't run through the building. Aesthetic concerns prevented Barker from attaching the conduit to the outside of the building. Barker finally decided to bury the conduit outside. He considered trenching, but this presented another problem: The concrete ramp of a delivery dock stretched nearly 40 ft from the building in the area between the panel and the meter. Trenching around it would mean saw-cutting concrete slabs. Directional boring seemed to be the last option. A hole bored beneath the ramp would provide a path through which the conduit could be pulled.

Barker called St. Louis-based Collins & Hermann, a subcontractor with a directional boring rig. Because of limited space, Barker decided to use Bore-Gard, a modified standard schedule 40 PVC “stick pipe” developed by Carlon of Cleveland. This UL-listed conduit, designed specifically for directional boring applications, would provide a fast joining method that wouldn't require glue.

Collins & Hermann cut holes in the asphalt patching at the bore end and at the pull end. They bored the hole about 5 ft beneath the footings of the concrete ramp. Once the bore head entered the pit at the other end, workers switched the bore head for a 6½-in. backreamer, and the conduit was hooked with a pull head. Then, they pulled the conduit through the hole.

According to Glen Marstall, facilities manager for Express Scripts, the job was done well within the critical timeframe and cost less than the budgeted amount for the project. Shrewd responses to mounting complexities had saved the day.


Want to use this article? Click here for options!





Acceptable Use Policy
blog comments powered by Disqus

what's wrong here?

What's Wrong Here?

Feb 2, 2012 7:54 PM

What's Wrong Here?

Jan 19, 2012 4:06 PM

What's Wrong Here?

Jan 5, 2012 11:53 AM

View all What's Wrong Here?

product spotlight

Labeling tool

Feb 10, 2012 7:58 AM

Labeling tool

The Rhino 4200 labeling tool features one-touch “hot keys” that quickly create and format wire/cable wraps, flags, fixed-length labels and more...

View all 2012 Product Spotlights

Free Product Info

Our Product Information site is the ultimate online resource for products and services offered by Advertisers featured in our Magazine. This service is provided as a quick and easy way to request Product Information online. Get FREE product information now.

Recent Comments

More...


Social Media

More ways to stay informed...

follow us on twitter

Find us on Facebook

EC&M TV

Arlington CP9000

Arlington's new 9" diameter ceiling cover plate is the neatest way to cover unused "high hat" cans. With no tools needed, installation couldn't be faster!...

Arlington Gangable Boxes

Designed for new or retrofit applications, these snap-together gangable plastic boxes eliminate the need to construct a multiple-gang steel box out of several individual ones...

Understanding NEC Requirements for Solar Photovoltaic Systems
During this session, Mike Holt will address possible conflicts or confusing NEC requirements, provide tips on proper electrical installation techniques, and discuss the dangers related to improper installations. View this On Demand Webinar!



resources

product info icon

product info

tradeshow icon

tradeshow

research icon

research

industry links

industry links

rss icon

rss

Browse Back Issues

Browse Back Issues