Arranged to drain

July 1, 2001
The cover on this conduit body, which is below the cabinet enclosing a panelboard installed indoors, was removed to allow rain water that accumulated during storms to be drained into the convenient waste line below it. The waste line was run to the outside of this electrical equipment room. Sections 225-22 and 230-53 both require raceways to drain when they are used to enclose branch circuit, feeder
The cover on this conduit body, which is below the cabinet enclosing a panelboard installed indoors, was removed to allow rain water that accumulated during storms to be drained into the convenient waste line below it. The waste line was run to the outside of this electrical equipment room. Sections 225-22 and 230-53 both require raceways to drain when they are used to enclose branch circuit, feeder and service-entrance conductors run on exterior surfaces of buildings that are exposed to weather. The raceways, except flexible metal conduit (see Section 350-5(1)) are supposed to be raintight and arranged to drain. Article 100 defines “raintight” as being constructed or “protected” so that exposure to a beating rain will not result in the entrance of water under specified test conditions. These Code rules should never be interpreted to allow rain to drain on electrical equipment.To see the complete article, view the PDF by clicking here.
About the Author

Joseph A. Tedesco

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.