Mike Holt

Mike
Holt
NEC Trainer / Consultant,
Mike Holt Enterprises
617

Mike earned a masters degree in the Business Administration Program (MBA) from the University of Miami. He earned his reputation as a National Electrical Code (NEC) expert by working his way up through the electrical trade. Formally a construction editor for two different trade publications, Mike started his career as an apprentice electrician and eventually became a master electrician, an electrical inspector, a contractor, and an educator. Since 1975, he has provided custom in-house seminars for groups such as IAEI, NECA, ICBO, IBM, AT&T, Motorola, and the U.S. Navy. Mike has taught more than 1,000 classes on 30 different electrical-related subjects — ranging from alarm installations to exam preparation and voltage drop calculations. He continues to develop seminars, videos, books, and software as well as contributing monthly Code content to EC&M magazine.

Articles
Everything You Need to Know About Services 
Among the ways service conductor requirements differ from those for branch circuit and feeder conductors is service conductors for one structure can’t pass through the interior of another structure [230.3].
Code Q&A: Securing and Supporting PVC Raceway 
Q. What is the Code rule for the securing and supporting of PVC raceways? Answer based on 2011 NEC.
Code Q&A: Wiring Methods Allowed in Hazardous Locations  3
Q. What wiring methods does the NEC permit in a Class I, Div. 1 location?
Branch Circuits and the NEC 
A branch circuit consists of the conductors between the final overcurrent protection device (OCPD) and the point of use outlets [Art. 100].
Stumped by the Code? Rules for Sizing Feeder Conductors 
Q. What is the Code rule for sizing feeder conductors, both ungrounded and neutral? Please show an example.
Code Q&A: Equipment Grounding Conductor in PVC?  2
Q. Is an equipment grounding conductor always required in a PVC raceway between the electric utility meter and service disconnect?
Code Q&A: Sizing Conductors for Single Motor 
Q. How do I size the conductors and protection device for a single motor?
Basic Requirements for Electrical Installations  1
Article 110 contains some of the most important but neglected parts of the Code. It also answers these basic questions:
Stumped by the Code? Rules for Securing and Supporting Raceways  1
Q. What are the NEC rules for securing and supporting raceways? Specifically compare EMT, FMC, and PVC.
Code Q&A: Smallest Approved Conductor  2
Q. What is the smallest conductor allowed by the NEC for branch circuits?
Code Q&A: Options Inside the Panel  2
Q. Can I make splices, taps, or install feed-through conductors in a panel?
Stumped by the Code? Types of Equipment Grounding Conductors Allowed by the NEC 
Q. What types of equipment grounding conductors does the NEC allow?
Small Wind Electric Systems 
When used for specific loads, small wind electric systems (SWESs) are often the sole power source.
Code Q&A: Minimum Cover Requirements 
Q. What are the minimum cover requirements for PVC and USE cable in commercial occupancies?
Code Q&A: Sizing EGC for Feeder Taps 

Q. What is the Code rule for sizing the equipment grounding conductor for feeder taps, and can you give me an example?

A. Equipment grounding conductors for feeder taps must be sized in accordance with Table 250.122, based on the ampere rating of the overcurrent device ahead of the feeder. In no case is it required to be larger than the feeder tap conductors [250.122(G)].