Eddie Guidry

Eddie
Guidry
Technical Director,
Fluor Enterprises, Inc.
20

Eddie Guidry is a technical director at Fluor Enterprises, Inc., Sugar Land, Texas. He is highly skilled in electrical and control systems for industrial construction, design, and engineering (both domestic and abroad). The majority of Eddie’s 36 years of experience includes upstream and downstream portions of petrochemical plants and refineries. He is also heavily experienced in water and wastewater treatment facilities. Eddie is very active in the development of U.S. national (ANSI) and international codes and standards, and has been a principal member of the National Fire Protection Association (NFPA) National Electrical Code (NEC) committee since 1999 and NFPA’s National Advisory Committee on Electrical Safety Research since 2008. Eddie, who has also developed and conducted many electrical courses and seminars over the years, currently holds the corporate Master Electrician license for Fluor Corporation in the State of Texas and is also an ICC/IAEI certified electrical inspector.

Articles
Building and Maintaining a Safe Substation Battery System 2
Substations are prevalent in all petrochemical facilities. Their function is to distribute power to the process units. Typically, there are either one or two types of battery systems within each substation.
Who’s Got the Power? 3
In Art. 100 of the 2014 National Electrical Code (NEC), the term Authority Having Jurisdiction (AHJ) is defined as “An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure.”
Type TC vs. Type TC-ER Cable
You may be in violation of the NEC without even knowing it.
Sensitive Electronic Grounding in Industrial Locations 5
Thirty to 35 years ago, distributed control systems (DCSs), along with new analog and digital instrument systems, were in their infancy.
Small Dry-Type Transformers and Appropriate OCPD Sizing 11
Most petrochemical industrial facilities have numerous small (30kVA or 45kVA) transformers spread throughout the process units serving lighting and power distribution panelboards.
Equipment Grounding Conductors and Voltage Drop 3
Currently, manufacturers of multi-conductor cable assemblies such as Type TC and MC cables include a standard size of equipment grounding conductor (EGC) with a given size of ungrounded conductor, as per UL standards.
The actuator in this photo is remotely mounted to a butterfly valve.
Does Your VAM Need a Local Disconnect? 5
The most common reference in the industry for valve actuator motors (VAMs) are motor operated valves (MOVs).
Analyzer Cable Tray Systems and the NEC
All petrochemical plants have analyzer shelters or stations.
Tank Farms and Conduit Sealing 2
Nearly all petrochemical facilities and refineries have tank farms that store feedstock or end products.
Welding Receptacles or Power Receptacles?
In petrochemical plants and refineries, there are usually many 480VAC, 3-phase receptacles scattered throughout the facility.
Pyrophoric Materials and NEC Article 500
In the 2014 Edition of the National Electrical Code (NEC), the last sentence of the first paragraph in Sec. 500.5(A) states: “Where pyrophoric materials are the only materials used or handled, these locations are outside the scope of this Article.”
Obstruction Clearances Behind Vertical Ladders
Not all requirements needed to make a safe installation are found in the National Electrical Code (NEC).
Hermetically Sealed or Factory Sealed
The 2014 edition of the National Electrical Code (NEC) [Sec. 500.7(J)] describes “hermetically sealed” as one of the protection techniques allowed in classified areas.
T-Codes in Hazardous (Classified) Locations
When using electrical equipment in classified areas, such as lighting fixtures in Class I, Div. 2 locations, it’s an NEC requirement that the surface temperature of the fixture doesn’t exceed 80% of the autoignition temperature (AIT) of the gas or vapor involved, or shall be marked with a temperature code (T-Code) [501.130(B)].
Medium-Voltage Cable Insulation Ratings 1
Below Table 310.104(E) in the 2014 National Electrical Code (NEC) are important notes that could be critical in the type of insulation that is specified or purchased for industrial locations.
Electrical Testing Feed

EC&M Webinars
Jul 21, 2015
Sponsored

Mitigation Methods for Arc Flash Hazards - Enhancing Personal Safety

The energy released during an arc flash event can result in severe damage to personnel, equipment, and property. While there are solutions which seek to improve the protection for each, this program will focus on personnel....More
Jul 14, 2015
Sponsored

Understanding the 2015 Edition of NFPA 70E and the Arc Flash Hazard

Get more information on the important changes to the 2015 edition of NFPA 70E. More specifically, this event will address hazard analysis and FR clothing performance testing, focusing on the quantification of incident energy and ATPV (or Arc Rating)....More